EasyManua.ls Logo

Xima L100 - Initial Parameters Setup

Xima L100
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
o Initial Parameters
Parameter
Name
Setting range
Default
Type

Normal Speed
0.00-2.50 m/s
1.00
R/W
Normal speed in the elevator speed settings

Intermediate Speed
0.00-2.50 m/s
0.50
R/W
Intermediate speed in the elevator speed settings

Inspection Speed
0.00-2.50 m/s
0.30
R/W
Inspection speed in the elevator speed settings

Leveling Speed
0.00-2.50 m/s
0.10
R/W
Leveling speed in the elevator speed settings
Fig. 16: Speed vs. Time diagram of the elevator in Open-loop mode

Acceleration
0.00-1.00 m/s
2
0.50
R/W
Startup acceleration in m/s
2

Jerk 1
0.00-5.00 m/s
3
0.10
R/W
Jerk at the start of movement in m/s
3

Jerk 2
0.00-5.00 m/s
3
0.20
R/W
Jerk at the end of movement in m/s
3







