Xima L100 - System Parameters Configuration

Xima L100
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
Parameter
Name
Setting range
Default value
Type

Multi Speed 3
0.00-2.50 m/s
0.30
R/W
Multi Speed 3

Multi Speed 4
0.00-2.50 m/s
0.50
R/W
Multi Speed 4

Multi Speed 5
0.00-2.50 m/s
0.70
R/W
Multi Speed 5

Multi Speed 6
0.00-2.50 m/s
0.80
R/W
Multi Speed 6

Multi Speed 7
0.00-2.50 m/s
1.00
R/W
Multi Speed 7

Rescue Time 1
0-100 s
5
R/W
Delay time before connecting the relay of enabling the control panel in
the delayed rescue mode

Rescue Time 2
1-1000 s
200
R/W
Connection time of relay of enabling the control panel in the delayed
rescue mode
o System Parameters
Parameter
Name
Setting range
Default value
Type

Password
0-9999
0
R/W
If this parameter is set to a non-zero number, you must first enter this
number as a password when you are entering the parameter setting
page .
It is better to keep the parameter 0 before the settings are finalized,
because it is easier to enter the parameters page. After finalizing the
settings, set this parameter to a desired number to prevent the
parameters being changed by other people.
Note that you must select a value not easily forgotten, and save it in a
safe place if possible .
If you forgot this parameter value, contact the company.

Restore/Back-up
0-4
0
R/W
Dummy State: Nothing happens.

Restore to Default: set this parameter to 1 and hold ENTER for 5
seconds, the drive saves the current parameter values into the
device memory and restores all the parameters to their default
value.
