If the current exceeds 200% of the rated current, the device will demonstrate an over-current
fault right away.
Duration of overload
fault from rated load
(seconds)
Duration of overload fault
from cold installation
(seconds)
Overload
output current
to input current
80
190
115%
50
140
120%
30
100
130%
15
60
150%
10
40
170%
Table 4: Durations in which the device can tolerate the overload period
Note:
If the average motor power is larger than the rated power of the device for a long time, it will
demonstrate a low-power fault, which means that an inverter with a larger power should be
replaced. Note that all parameters, including faults, average, and maximum temperature,
current, voltage, etc., are stored in the memory of the device and evaluated for the warranty
validity.