Page #10 background image
1.7 EU declaration of conformity (No LVD/EMCD05)
1. Apparatus model/Product: data plate
2. Name and address of the manufacturer: Xylem Service Italia S.r.l.
Via Vittorio Lombardi 14
36100 Vicenza VI
Italy
3. This declaration of conformity is issued under the sole responsibility of the manufacturer.
4. Object of the declaration: Frequency converter (variable speed drive) HYDROVAR
®
for
electric pump in one of the following models
HVL2.015-A0010 HVL4.015-A0010
HVL2.022-A0010 HVL4.022-A0010
HVL2.030-A0010 HVL4.030-A0010
HVL2.040-A0010 HVL4.040-A0010
HVL3.015-A0010 HVL4.055-A0010
HVL3.022-A0010 HVL4.075-A0010
HVL3.030-A0010 HVL4.110-A0010
HVL3.040-A0010 HVL4.150-A0010
HVL3.055-A0010 HVL4.185-A0010
HVL3.075-A0010 HVL4.220-A0010
HVL3.110-A0010
5. The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:
Directive 2014/35/UE of 26 February 2014 (electrical equipment designed for use within certain voltage limits)
Directive 2014/30/UE of 26 February 2014 (electromagnetic compatibility)
6. References to the relevant harmonised standards used or references to the other technical specifications in
relation to which conformity is declared:
EN 61800-5-1:2007
EN 61800-3:2004+A1:2012 (*), EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011
(*) Category C3
7. Notified body: -
8. Additional information: -
Signed for and on behalf of: Xylem Service Italia S.r.l.
Montecchio Maggiore,18/04/2016
Amedeo Valente
Director of Engineering and R&D
Rev. 00
1.8 EU declaration of conformity
1. Unique identification of the EEE: No HVL
2. Name and address of the manufacturer: Xylem Service Italia S.r.l.
Via Vittorio Lombardi 14
36100 Vicenza VI
Italy
3. This declaration of conformity is issued under the sole responsibility of the manufacturer.
1 Introduction and Safety
8 HVL 2.015-4.220 Installation, Operation, and Maintenance Manual

Table of Contents

Other manuals for Xylem hydrovar

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem hydrovar and is the answer not in the manual?

Xylem hydrovar Specifications

General IconGeneral
Frequency50/60 Hz
Control typeVariable speed drive
Protection classIP55
Communication protocolsModbus
Relative Humidity5% - 95% (non-condensing)
AltitudeUp to 1000 m without derating
Input voltage200-690 V AC
Storage Temperature-25°C to +70°C (-13°F to 158°F)