1.21 Defaults by Drive Model and Duty Rating ND/HD
142 YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
No.
*1
Name Unit Default
- Drive Model - 4060
C6-01
Normal / Heavy Duty
Selection
-
HD ND
0 1
o2-04 Drive Model (KVA) Selection Hex. 9F
E2-11
(E4-11, E5-02)
Motor Rated Power kW 22 30
b3-04 V/f Gain during Speed Search % 100 100
b3-06 Speed Estimation Current Level 1 - 0.5 0.5
b3-08 Speed Estimation ACR P Gain - 0.5 0.5
b3-26 Direction Determination Level - 1000 1000
b8-03 Energy Saving Filter Time s 0.5 0.5
b8-04 Energy Saving Coefficient Value - 103.58 92.54
C6-02 Carrier Frequency Selection - 3 7
E2-01
(E4-01)
Motor Rated Current (FLA) A 38.6 52.3
E2-02
(E4-02)
Motor Rated Slip Hz 1.7 1.8
E2-03
(E4-03)
Motor No-Load Current A 9.2 10.9
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 0.316 0.269
E2-06
(E4-06)
Motor Leakage Inductance % 23.5 20.7
E2-10
(E4-10)
Motor Iron Loss W 586 750
E5-01 PM Motor Code Selection - FFFF FFFF
L2-02 Power Loss Ride Through Time s 2 2
L2-03 Minimum Baseblock Time s 1 1.1
L2-04
Powerloss V/f Recovery Ramp
Time
s 0.6 0.6
L2-05 Undervoltage Detection Lvl (Uv1) - 380 380
L3-02 Stall Prevent Level during Accel % 150 120
L3-06 Stall Prevent Level during Run % 150 120
L3-24 Motor Accel Time @ Rated Torque s 0.355 0.323
L8-02 Overheat Alarm Level °C 115 115
L8-09 Output Ground Fault Detection - 1 1
n1-03 Hunting Prevention Time Constant ms 10 10
n3-02
HSB Current Limit Level
% 150 120
n5-02 Motor Inertia Acceleration Time s 0.355 0.323
*1 Parameters within parentheses are for motor 2.