Parameter Details
2
2.2 A: Initialization Parameters
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 151
No. Name Optimal Value
C6-01 Normal / Heavy Duty Selection 1: Normal Duty Rating
E1-03 V/f Pattern Selection F: Custom
E1-07 Mid Point A Frequency 30.0 Hz
E1-08 Mid Point A Voltage 50.0 V
L2-01 Power Loss Ride Through Select 1: Enabled
L3-04 Stall Prevention during Decel 1: General Purpose
The drive saves the parameters in Table 2.5 as User Parameters.
Table 2.5 Parameters Saved as User Parameters with the Water Supply Pump Preset
User Parameter No. Parameter No. Saved Name
A2-01 b1-01 Frequency Reference Selection 1
A2-02 b1-02 Run Command Selection 1
A2-03 b1-04 Reverse Operation Selection
A2-04 C1-01 Acceleration Time 1
A2-05 C1-02 Deceleration Time 1
A2-06 E1-03 V/f Pattern Selection
A2-07 E1-07 Mid Point A Frequency
A2-08 E1-08 Mid Point A Voltage
A2-09 E2-01 Motor Rated Current (FLA)
A2-10 H1-05 Terminal S5 Function Selection
A2-11 H1-06 Terminal S6 Function Selection
A2-12 H1-07 Terminal S7 Function Selection
A2-13 L5-01 Number of Auto-Restart Attempts
2 : Conveyor
The drive automatically sets the parameters in Table 2.6 for a conveyor application.
Table 2.6 Best Parameter Settings for Conveyor Applications
No. Name Optimal Value
A1-02 Control Method Selection 0: V/f Control
C1-01 Acceleration Time 1 3.0 s
C1-02 Deceleration Time 1 3.0 s
C6-01 Normal / Heavy Duty Selection 0: Heavy Duty Rating
L3-04 Stall Prevention during Decel 1: General Purpose
The drive saves the parameters in Table 2.7 as User Parameters.
Table 2.7 Parameters Saved as User Parameters with the Conveyor Preset
User Parameter No. Parameter No. Saved Name
A2-01 A1-02 Control Method Selection
A2-02 b1-01 Frequency Reference Selection 1
A2-03 b1-02 Run Command Selection 1
A2-04 C1-01 Acceleration Time 1
A2-05 C1-02 Deceleration Time 1
A2-06 E2-01 Motor Rated Current (FLA)
A2-07 L3-04 Stall Prevention during Decel

Table of Contents

Related product manuals