Parameter Details
2
2.8 H: Terminal Function Selection
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 317
H2-37: Comparator 2 Ineffective Time
No.
(Hex.)
Name Description
Default
(Range)
H2-37
(159F)
Comparator 2 Ineffective
Time
Sets the length of time that CP2 [Comparator2 Limit Fault] is disabled.
0.0 s
(0.0 - 1000.0 s)
Note:
After you enter a Run command and wait for the time set in this parameter, the drive will monitor operation and make sure that it is in the
Comparator 2 range until you enter the Stop command.
When CP2 detection is disabled, the drive will activate the output terminal set for Comparator 2 [H2-xx = 67].
H2-40: Mbus Reg 15E0h bit0 Output Func
No.
(Hex.)
Name Description
Default
(Range)
H2-40
(0B58)
Mbus Reg 15E0h bit0
Output Func
Sets the MFDO for bit 0 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1FF)
H2-41: Mbus Reg 15E0h bit1 Output Func
No.
(Hex.)
Name Description
Default
(Range)
H2-41
(0B59)
Mbus Reg 15E0h bit1
Output Func
Sets the MFDO for bit 1 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1FF)
H2-42: Mbus Reg 15E0h bit2 Output Func
No.
(Hex.)
Name Description
Default
(Range)
H2-42
(0B5A)
Mbus Reg 15E0h bit2
Output Func
Sets the MFDO for bit 2 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1FF)
H2-60: Term MA,MB,MC Secondary Function
No.
(Hex.)
Name Description
Default
(Range)
H2-60
(1B46)
Expert
Term MA,MB,MC
Secondary Function
Sets the second function for terminal MA/MB-MC. Outputs the logical calculation results of the
terminals set to functions by H2-01 [Term MA,MB,MC Function Selection].
F
(0 - FF)
H2-61: Term MA,MB,MC Logical Operation
No.
(Hex.)
Name Description
Default
(Range)
H2-61
(1B47)
Expert
Term MA,MB,MC Logical
Operation
Sets the logical operation for the functions set in H2-01 [Term MA,MB,MC Function Selection] and
H2-60 [Term MA,MB,MC Secondary Function].
0
(0 - 8)
Note:
Refer to Output of Logical Operation Results of MFDO on page 311 for more information about the relation between parameter settings and
logical operations.
H2-62: Term MA,MB,MC Minimum ON Time
No.
(Hex.)
Name Description
Default
(Range)
H2-62
(1B48)
Expert
Term MA,MB,MC
Minimum ON Time
Sets the minimum ON time that the drive uses to output the logical calculation results from terminal
MA/MB-MC.
0.1 s
(0.0 - 25.0 s)
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Related product manuals