Setting Value Function Description
93 DWEZ Digital Input 4
Sets the DriveWorksEZ digital input 4. Refer to the DriveWorksEZ online manual for more information.
94 DWEZ Digital Input 5
Sets the DriveWorksEZ digital input 5. Refer to the DriveWorksEZ online manual for more information.
95 DWEZ Digital Input 6
Sets the DriveWorksEZ digital input 6. Refer to the DriveWorksEZ online manual for more information.
96 DWEZ Digital Input 7
Sets the DriveWorksEZ digital input 7. Refer to the DriveWorksEZ online manual for more information.
97 DWEZ Digital Input 8
Sets the DriveWorksEZ digital input 8. Refer to the DriveWorksEZ online manual for more information.
9F DWEZ Disable
Sets operation of the DriveWorksEZ program saved in the drive.
ON : Disabled
OFF : Enabled
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Enabled/Disabled wDigital Input] to use this function.
101
!LOCAL/REMOTE
Selection
Sets drive control for the keypad (LOCAL) or an external source (REMOTE).
ON : REMOTE
OFF : LOCAL
102 !External Reference 1/2
Selection
Sets the drive to use Run command source 1/2 or Reference command source 1/2 when in REMOTE Mode.
ON : b1-01 = [Frequency Reference Selection 1], b1-02 [Run Command Selection 1]
OFF : b1-15 = [Frequency Reference Selection 2], b1-16 [Run Command Selection 2]
103 !Multi-Step Speed Reference
1
Uses a combination of multi-step speed references 1, 2 and 3 (N.C.) to set d1-01 to d1-08 [Multi-Step Speed Reference].
104 !Multi-Step Speed Reference
2
Uses a combination of multi-step speed references 1, 2 and 3 (N.C.) to set d1-01 to d1-08 [Multi-Step Speed Reference].
105 !Multi-Step Speed Reference
3
Uses a combination of multi-step speed references 1, 2 and 3 (N.C.) to set d1-01 to d1-08 [Multi-Step Speed Reference].
106 !Jog Reference Selection
Sets the drive to use the JOG Frequency Reference (JOG command) set in d1-17 [Jog Reference]. The JOG Frequency Reference
(JOG command) overrides the d1-01 to d1-16 [References 1 to 16].
107 !Accel/Decel Time Selection
1
Sets the drive to use C1-01, C1-02 [Acceleration/Deceleration Time 1] or C1-03, C1-04 [Acceleration/Deceleration Time 2].
10A !Accel/Decel Ramp Hold
Momentarily pauses motor acceleration and deceleration when the terminal deactivates, retains the output frequency that was stored
in the drive at the time of the pause, and restarts motor operation.
10B !Overheat Alarm (oH2)
Sets the drive to display an oH2 [Drive Overheat Warning] alarm when the input terminal deactivates. The alarm does not have an
effect on drive operation.
10C !Analog Terminal Enable
Selection
Enables and disables the terminal selected with the H3-14 [Analog Input Term Enable Select] function.
ON : Input to the terminal selected with H3-14 is disabled
OFF : Input to the terminal selected with H3-14 is enabled
10D !Ignore Speed Fdbk (V/f w/o
Enc)
When the terminal deactivates, the drive ignores the feedback control from the encoder and operates in V/f control. When the
terminal activates, the drive uses the feedback from the encoder to control the motor speed again.
ON : Speed feedback control enable (Closed Loop V/f Control)
OFF : Speed feedback control disable (V/f Control)
10E !ASR Integral Reset
Sets the command to reset the integral value and use PI control or P control for the speed control loop.
ON : PI control
OFF : P control
110 !Up Command
Set this function and 111 [! Down Command] together. Sets the Up command and Down command to use the two push button
switches to increase and decrease the drive frequency reference.
ON : Holds the current frequency reference.
OFF : Increases the frequency reference.