3.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
276 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
No. Name Range Unit
Control Method (A1-02 Setting)
OLV/PM
(5)
AOLV/PM
(6)
CLV/PM
(7)
EZOLV
(8)
E1-08 Mid Point AVoltage 0.0 - 255.0
*7
0.1 V - - - -
E1-09
Minimum Output
Frequency
0.0 - 590.0
*6
0.1 Hz Determined by E5-01 Determined by E5-01 Determined by E5-01 -
E1-10
Minimum Output
Voltage
0.0 - 255.0
*7
0.1 V - - - -
E1-11 Mid Point B Frequency 0.0 - 590.0
*6
0.1 Hz - - - -
E1-12 Mid Point AVoltage 0.0 - 255.0
*7
0.1 V - - - -
E1-13 Base Voltage 0.0 - 255.0
*7
0.1 V - - - -
F1-01
Encoder 1 Pulse Count
(PPR)
0 - 60000 1 ppr - - 1024 -
F1-05
Encoder 1 Rotation
Selection
0 - 1 1 - - 1 -
F1-09
Overspeed Detection
Delay Time
0.0 - 2.0 0.1 s - 0.0 0.0 0.0
L1-01
Motor Overload (oL1)
Protection
0 - 6 1 4 4 5 1
*8
L2-31
KEB Start Voltage
Offset Level
0 - 100
*7
1 V 50 50 50 50
L3-05
Stall Prevention during
RUN
0 - 3 1 2 - - 3
L3-20
DC Bus Voltage
Adjustment Gain
0.00 - 5.00 0.01 0.65 0.65 0.65 0.65
L3-21
OVSuppression Accel/
Decel P Gain
0.10 - 10.00 0.01 1.00 1.00 1.00 1.00
L3-36
Current Suppression
Gain@Accel
0.0 - 100.0 0.1 - - - -
L4-01
Speed Agree Detection
Level
0.0 - 590.0
*10
0.1 0.0 Hz 0.0% 0.0% 0.0 Hz
L4-02
Speed Agree Detection
Width
0.0 - 20.0
*4
0.1 2.0 Hz 4.0% 4.0% 2.0 Hz
L4-03
Speed Agree Detection
Level(+/-)
-590.0 - +590.0
*10
*11
0.1 0.0 Hz 0.0% 0.0% 0.0 Hz
L4-04
Speed Agree Detection
Width(+/-)
0.0 - 20.0
*4
0.1 2.0 Hz 4.0% 4.0% 2.0 Hz
L8-38
Carrier Frequency
Reduction
0 - 2 1 0 - 0 0
L8-40
Carrier Freq Reduction
Off-Delay
0.00 - 2.00 0.01 s 0.00 - 0.00 0.00
L8-90
STPo Detection Level
(Low Speed)
0 - 5000 1 0 80 - 0
n1-15
PWM Voltage Offset
Calibration
0 - 2 1 1 1 1 1
n5-04
Speed Response
Frequency
0.00 - 500.00 0.01 Hz - 20.00 50.00 -
n8-35
Initial Pole Detection
Method
0 - 2 1 0 1 1 -
n8-51
Pull-in Current @
Acceleration
0 - 200 1% 50% - - 80%
o1-03
Frequency Display Unit
Selection
0 - 3 1 2 2 2 0
*9
o1-04 V/f Pattern Display Unit 0 - 1 1 - 1 1 0
*9
*1 The default setting is different for different models.
2138 - 2415, 4089 - 4720, T103 - T720: 0.30
*2 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.
*3 The setting range is 0.0 to 100.0 when A1-02 = 6 or 7 [PM Advanced Open Loop Vector or PM Closed Loop Vector].
*4 The setting range is 0.0 to 40.0 when A1-02 = 6 or 7 [PM Advanced Open Loop Vector or PM Closed Loop Vector].
*5 The default setting changes when C6-01 [Normal / Heavy Duty Selection] changes.