LED Display LCD Display Minor Fault Name
Insufficient suction pressure is present.
Shown when P4-24 = 1 and when the digital input has been active (closed for P4-21 = 0, or open for P4-21
= 1) for the time set in P4-22.
The drive, if running, coasts-to-stop and does not run until the digital input has been inactive for the time
set in P4-22.
LED Display LCD Display Minor Fault Name
Low Water in
Tank
Low Water in Tank
Cause Possible Solution
The water level in the tank is too low.
Shown when P4-24 = 2 and when the digital
input has been active (closed for P4-21 = 0,
or open for P4-21 = 1) for the time set in
P4-22.
Check pressure switch contact for correct operation.
Check control wiring to drive terminal strip from pressure switch contact.
Check to make sure that suction pressure is present by means of a separate measuring device.
Raise the water level.
LED Display LCD Display Minor Fault Name
lt-1
LT-1
Cooling Fan Maintenance Time
The cooling fan has reached its expected maintenance period and may need to be replaced.
Note:
An alarm output (H2-oo = 10) will only be triggered if both
(H2-oo = 2F and H2-oo = 10) are set.
Cause Possible Solution
The cooling fan has reached 90% of its
expected performance life.
Replace the cooling fan and set o4-03 to 0 to reset the Maintenance Monitor.
LED Display LCD Display Minor Fault Name
lt-2
LT-2
Capacitor Maintenance Time
The main circuit and control circuit capacitors are nearing the end of their expected performance life.
Note:
An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F.
Cause Possible Solution
The main circuit and control circuit capacitors
have reached 90% of their expected
performance lives.
Replace the drive.
LED Display LCD Display Minor Fault Name
lt-3
LT-3
Soft Charge Bypass Relay Maintenance Time
The DC bus soft charge relay is nearing the end of its expected performance life.
Note:
An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F.
Cause Possible Solution
The DC bus soft charge relay has reached
90% of expected performance life.
Replace the drive.
LED Display LCD Display Minor Fault Name
lt-4
LT-4
IGBT Maintenance Time (50%)
IGBTs have reached 50% of their expected performance life.
Note:
An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F.
Cause Possible Solution
IGBTs have reached 50% of their expected
performance life.
Check the load, carrier frequency, and output frequency.
LED Display LCD Display Minor Fault Name
net5c
NETSCAN
Waiting for
Master
NETSCAN
Drive is waiting for a message from the master.
Cause Possible Solution
No message was received from the master
within the time set in P9-28.
Increase the P9-26 setting to account for network latency.
Verify that there is a drive on the network with parameter P1-01 set to 3 and P9-27 to 0.
Check network connections and verify H5-01 and P9-25 settings for all drives on the network.
6.4 Alarm Detection
274
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual