YASKAWA TOMPYEULA5001C LA500 Installation and Operation Instructions 23
User Parameter Parameter Name
A2-15 d1-07 Speed Reference 7
A2-16 d1-08 Speed Reference 8
A2-17 d1-28 Nominal/Leveling Spd Detection
A2-18 d1-29 Inspection Speed Detection
A2-19 C1-01 Acceleration Time 1
A2-20 C1-02 Deceleration Time 1
A2-21 C2-01 S-Curve @ Start of Acceleration
A2-22 C2-02 S-Curve @ End of Acceleration
A2-23 C2-03 S-Curve @ Start of Deceleration
A2-24 C2-04 S-Curve @ End of Deceleration
A2-25 C2-05 Jerk @ Levelig
A2-26 E2-03 Motor No-Load Current
A2-27 S1-02 DC-Injection @ Start
A2-28 S1-03 DC-Injection @ Stop
A2-29 S1-06 Brake Open Delay
A2-30 S1-07 Brake Close Delay
A2-31
User Parameter Selection
A2-32
A2-33
◆ Drive Parameters
Refer to the following table when you set the most important parameters.
Note:
You can change parameters that have “RUN” in the “No.” column during drive operation.
No.
(Hex.)
Name Description
A1-02 Control Method
Selection
Sets the control method for the drive application and the motor.
0: V/f Control, 2: Open Loop Vector
A1-03 Initialize Parameters Sets parameters to default values.
0: No Initialization, 1110: User Initialization, 2220: 2-Wire Initialization
b1-02 Run Command
Selection 1
Sets the input method for the Run command.
0: Keypad, 1: Digital Input
b1-03 Stopping Method
Selection
Sets the method to stop the motor after removing a Run command or entering a
Stop command.
0: Ramp to Stop, 1: Coast to Stop