OPERATION
ArcWorld IV-6200 XHD DR2C System Manual 5-2 MOTOMAN
With the programming pendant, the operator can develop a series of jobs for the
robots. You can program the robots independently, the station axis independently,
or the robots and station axis together. You must select the axis combination when
teaching the job initially (see Section 5.1.4). Motoman recommends programming
the robots and station axis together to reduce the risk of interference.
NOTE: Refer to your system’s Independent/Coordinated Motion Manual (P/N 142969-1) for
information on coordinated motion, selecting synchronization, group axes, and tooling
calibration.
CAUTION!
Remember that only the Tool Center Point (TCP) location on the robot
is recognized by the controller. Without careful programming, the
robot arm could still damage other equipment.
5.1.1 I/O Assignment
The ArcWorld IV-6200 XHD DR2C cell uses the following user and dedicated
inputs and outputs (see Table 5-1 and Table 5-2).
For more information on user and dedicated I/O’s, refer to the Concurrent I/O &
Parameter Manual (P/N 147626-1).
XRC 2001 Dedicated Inputs XRC 2001 Dedicated Outputs
Table 5-1 XRC 2001 User Inputs
Input Assignment Description
IN#001thru 008 NOT USED
IN#009 CYCLE START Cycle start input from operator station.
IN#010 AUTO/MANUAL SELECT Auto/manual mode from operator
station.
IN#011 LIGHT CURTAIN CLEAR Signal from light curtain controller to
verify operator is clear.
IN#012 SAFETY RELAY CR4101 FAULTED Indication of safety relay fault. Cycle
controller power to reset.
IN#013 SAFETY RELAY CR4121 FAULTED Indication of safety relay fault. Cycle
controller power to reset.
IN#014 AT SIDE B Robots are at positioner Side B.
IN#015 AT SIDE A Robots are at positioner Side A.
IN#016 NOT USED
Servo On
External Job Start
Alarm Reset
REMOTE mode ON
Hold
External Emergency Stop
Servo Power ON
TEACH mode
Cube 23
Cube 24
Alarm Occurrence

Table of Contents