EasyManua.ls Logo

YASKAWA MOTOMAN-MS165 - 4 Wiring; 4.1 Grounding

YASKAWA MOTOMAN-MS165
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-1
167109-1CD
HW1482308
4 Wiring
4.1 Grounding
MS165
4 Wiring
4.1 Grounding
Follow electrical installation standards and wiring regulations for
grounding. A ground wire of 5.5 mm
2
or more is recommended.
Refer to fig. 4-1 “Grounding Method” to connect the ground line directly
to the manipulator.
WARNING
Ground resistance must be 100 or less.
Failure to observe this warning may result in fire or electric shock.
Before wiring, make sure to turn the primary power supply off, and
put up a warning sign. (ex. DO NOT TURN THE POWER ON.)
Failure to observe this warning may result in fire or electric shock.
CAUTION
Wiring must be performed by authorized or certified personnel.
Failure to observe this caution may result in fire or electric shock.
Do not cover the cable or allow it to tangle. Keep the cable as
straight as possible.
Failure to observe this caution may result in preventing heat of the
cable from being discharged.
NOTE
• Never use this line sharing with other ground lines or
grounding electrodes for other electric power, motor
power, welding devices, etc.
• Where metal ducts, metallic conduits, or distributing racks
are used for cable laying, ground in accordance with elec-
trical installation standards.
26 of 100

Table of Contents

Related product manuals