Sigma II User’s Manual Chapter 8: Ratings and Characteristics
8 - 32
*1
Allowable regenerative frequency is the number of times the servomotor is allowed to accelerate
and decelerate through a 0rpm maximum motor speed 0rpm cycle in a minute.
Voltage Three-phase 200V
Servo Amplifier Model
SGDH-
10AE 15AE 20AE 30AE 40AE 50AE
SGMSH Series
Applicable
Servo-motor
Model
SGMSH-
10A 15A 20A 30A 40A 50A
Capacity
(kW)
1.0 1.5 2.0 3.0 4.0 5.0
Motor
Speed
(rpm)
Rated 3000/maximum 5000
Applicable Encoder
Standard: 17-bit incremental encoder
Continuous
Output Current
A
rms
5.7 9.7 12.7 18.8 25.4 28.6
Maximum
Output Current
A
rms
17 28 42 56 77 84
Allowable
Regenerative
Frequency
*1
(times/min)
39 31 48 20 29 22