EasyManua.ls Logo

YOKOGAWA DL9040

YOKOGAWA DL9040
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-97
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>:AREA<x>:
TYPE?
Function Queries all settings related to the waveform
parameters of the measure determination.
Syntax
:GONogo:ZPARameter:SELect<x>:PARameter:
MEASure:TRACe<x>:AREA<x>:TYPE?
<x> of SELect<x> = 1 to 4
<x> of
TRACe<x> = 1 to 8
<x> of AREA<x> = 1 or 2
Example
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:TRACE1:AREA1:TYPE? -> :GONOGO:
ZPARAMETER:SELECT1:PARAMETER:
MEASURE:TRACE1:AREA1:TYPE:
MAXIMUM 2.000E+00,1.000E+00
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>:AREA<x>:
TYPE:<Parameter>
Function Sets the upper and lower limits of the waveform
parameter of the measure determination or queries
the current setting.
Syntax
:GONogo:ZPARameter:SELect<x>:PARameter:
MEASure:TRACe<x>:AREA<x>:TYPE:
<Parameter> {<NRf>,<NRf>|
<Voltage>,<Voltage>|
<Current>,<Current>|<Time>,<Time>|
<Frequency>,<Frequency>}
:GONogo:ZPARameter:SELect<x>:PARameter:
MEASure:TRACe<x>:AREA<x>:TYPE:
<Parameter>?
<x> of SELect<x> = 1 to 4
<x> of
TRACe<x> = 1 to 8
<x> of AREA<x> = 1 or 2
<Parameter> = {BURSt|CMEan|COUNt|CRMS|
CSDeviation|DELay|DT|DUTYcycle|FALL|
FREQuency|HIGH|HILow|LOW|MAXimum|MEAN|
MINimum|NOVershoot|NWIDth|PERFrequency|
PERiod|POVershoot|PTOPeak|PWIDth|RISE|
RMS|SDEViation|TYCInteg|TYINteg|V1|V2}
<NRf>, <V
oltage>, <Current>, <T
ime>, and
<Frequency> = See the DL9000 User’s Manual.
Example (The following is an example for the maximum value
of trace 1 and area 1.)
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:TRACE1:AREA1:TYPE:MAXIMUM 1,2
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:TRACE1:AREA1:TYPE:MAXIMUM?
-> :GONOGO:ZPARAMETER:SELECT1:
PARAMETER:MEASURE:TRACE1:AREA1:TYPE:
MAXIMUM 2.000E+00,1.000E+00
Description
This command applies to cycle statistical processing
when
:MEASURE:MODE CYCLE
.
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:STATistics
Function Sets the statistical value of the measure determination
or queries the current setting.
Syntax
:GONogo:ZPARameter:SELect<x>:PARameter:
MEASure:STATistics {MAXimum|MEAN|
MINimum|SIGMa}
:GONogo:ZPARameter:SELect<x>:PARameter:
MEASure:STATistics?
<x> = 1 to 4
Example
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:STATISTICS MAXIMUM
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:STATISTICS? ->
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:STATISTICS MAXIMUM
Description This command is valid when
:MEASURE:MODE
CYCLE
.
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>?
Function Queries all settings related to the trace of the
measure determination.
Syntax
:GONogo:ZPARameter:SELect<x>:PARameter:
MEASure:TRACe<x>?
<x> of SELect<x> = 1 to 4
<x> of
TRACe<x> = 1 to 8
Example
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:TRACE1? -> :GONOGO:ZPARAMETER:
SELECT1:PARAMETER:
MEASURE:TRACE1:AREA1:TYPE:
MAXIMUM 2.000E+00,1.000E+00
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>:AREA<x>?
Function Queries all settings related to the area of the measure
determination.
Syntax
:GONogo:ZPARameter:SELect<x>:PARameter:
MEASure:TRACe<x>:AREA<x>?
<x> of SELect<x> = 1 to 4
<x> of
TRACe<x> = 1 to 8
<x> of AREA<x> = 1 or 2
Example
:GONOGO:ZPARAMETER:SELECT1:PARAMETER:
MEASURE:TRACE1:AREA1? -> :GONOGO:
ZPARAMETER:SELECT1:PARAMETER:
MEASURE:TRACE1:AREA1:TYPE:
MAXIMUM 2.000E+00,1.000E+00
5.12 GONogo Group