5-108
IM 701310-17E
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:XY<x>:XYINteg
Function Sets the upper and lower limits integral value of the
XY search or queries the current setting.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:XY<x>:XYINteg {<NRf>,<NRf>}
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:XY<x>:XYINteg?
<x> of SELect<x> = 1 to 4
<x> of XY<x> = 1 or 2
<NRf> = –4 to 4 (div)
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:XY1:XYINTEG 1,2
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:XY1:XYINTEG? -> :HISTORY:
CURRENT:SEARCH:SELECT1:
PARAMETER:XY1:
XYINTEG 2.000E+00,1.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
RECTangle?
Function Queries all settings related to the rectangle search.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
RECTangle?
<x> = 1 to 4
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
RECTANGLE? -> :HISTORY:CURRENT:SEARCH:
SELECT1:RECTANGLE:HORIZONTAL 2.000E+00,
1.000E+00;VERTICAL 2.000E+00,1.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
RECTangle:HORizontal
Function Sets the horizontal position of the rectangle used in
the rectangle search or queries the current setting.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
RECTangle:HORizontal {<NRf>,<NRf>}
:HISTory[:CURRent][:SEARch]:SELect<x>:
RECTangle:HORizontal?
<x> = 1 to 4
<NRf> = –5 to 5 (div)
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
RECTANGLE:HORIZONTAL 1,2
:HISTORY:CURRENT:SEARCH:SELECT1:
RECTANGLE:HORIZONTAL? -> :HISTORY:
CURRENT:SEARCH:SELECT1:RECTANGLE:
HORIZONTAL 2.000E+00,1.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:MEASure:TRACe<x>:AREA<x>:
TYPE:<Parameter>
Function Sets the upper and lower limits of the waveform
parameter of the measure search or queries the
current setting.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:MEASure:TRACe<x>:AREA<x>:
TYPE:<Parameter> {(<NRf>,<NRf>)|
(<Voltage>,<Voltage>)|
(<Current>,<Current>)|(<Time>,<Time>)|
(<Frequency>,<Frequency>)}
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:MEASure:TRACe<x>:AREA<x>:
TYPE:<Parameter>?
<x> of SELect<x> = 1 to 4
<x> of
TRACe<x> = 1 to 8
<x> of AREA<x> = 1 or 2
<Parameter> = {BURSt|CMEan|COUNt|CRMS|
CSDeviation|DELay|DT|DUTYcycle|FALL|
FREQuency|HIGH|HILow|LOW|MAXimum|MEAN|
MINimum|NOVershoot|NWIDth|PERFrequency|
PERiod|POVershoot|PTOPeak|PWIDth|RISE|
RMS|SDEViation|TYCInteg|TYINteg|V1|V2}
<NRf>, <Voltage>, <Current>, <T
ime>, and
<Frequency> = See the DL9000 User’s Manual.
Example (The following is an example for the maximum value
of trace 1 and area 1.)
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:MEASURE:TRACE1:AREA1:TYPE:
MAXIMUM 0,1
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:MEASURE:TRACE1:AREA1:TYPE:
MAXIMUM? -> :HISTORY:CURRENT:SEARCH:
SELECT1:PARAMETER:MEASURE:TRACE1:AREA1:
TYPE:MAXIMUM 1.000E+00,0.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:XY<x>?
Function Queries all settings related to the XY search.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:XY<x>?
<x> of SELect<x> = 1 to 4
<x> of XY<x> = 1 or 2
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:XY1? -> :HISTORY:CURRENT:
SEARCH:SELECT1:PARAMETER:XY1:
XYINTEG 2.000E+00,1.000E+00
5.14 HISTory Group

Table of Contents

Related product manuals