5-191
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:TRIGger:ENHanced:SPATtern:LATCh:
POLarity
Function Sets the polarity of the latch trace of the serial pattern
trigger or queries the current setting.
Syntax
:TRIGger:ENHanced:SPATtern:LATCh:
POLarity {FALL|RISE}
:TRIGger:ENHanced:SPATtern:LATCh:
POLarity?
Example
:TRIGGER:ENHANCED:SPATTERN:LATCH:
POLARITY FALL
:TRIGGER:ENHANCED:SPATTERN:LATCH:
POLARITY? -> :TRIGGER:ENHANCED:
SPATTERN:LATCH:POLARITY FALL
Description This command is valid when
:TRIGger:
ENHanced:SPATtern:CLOCk:MODE ON
.
This command in invalid if
:TRIGger:ENHanced:
SPATtern:LATCh:SOURce NONE
.
:TRIGger:ENHanced:SPATtern:LATCh:
SOURce
Function Sets the latch trace of the serial pattern trigger or
queries the current setting.
Syntax
:TRIGger:ENHanced:SPATtern:LATCh:
SOURce {<NRf>|NONE}
:TRIGger:ENHanced:SPATtern:LATCh:
SOURce?
<NRf> = 1 to 4
Example
:TRIGGER:ENHANCED:SPATTERN:LATCH:
SOURCE 1
:TRIGGER:ENHANCED:SPATTERN:LATCH:
SOURCE? -> :TRIGGER:ENHANCED:SPATTERN:
LATCH:SOURCE 1
Description This command is valid when
:TRIGger:ENHanced:
SPATtern:CLOCk:MODE ON
.
:TRIGger:ENHanced:SPATtern:PATTern
Function Sets the pattern of the serial pattern trigger in binary
notation or queries the current setting.
Syntax
:TRIGger:ENHanced:SPATtern:
PATTern {<String>}
:TRIGger:ENHanced:SPATtern:PATTern?
<String> = Up to 128 characters by combining ‘0’, ‘1’,
and ‘X’
Example
:TRIGGER:ENHANCED:SPATTERN:PATTERN
"1100110111101111"
:TRIGGER:ENHANCED:SPATTERN:PATTERN?
-> :TRIGGER:ENHANCED:SPATTERN:
PATTERN "1100110111101111"
:TRIGger:ENHanced:SPIBus?
Function Queries all settings related to the SPI bus trigger.
Syntax
:TRIGger:ENHanced:SPIBus?
Example
:TRIGGER:ENHANCED:SPIBUS? -> :TRIGGER:
ENHANCED:SPIBUS:BITORDER LSBFIRST;
CLOCK:POLARITY FALL;SOURCE 1;:TRIGGER:
ENHANCED:SPIBUS:CS:ACTIVE HIGH;
SOURCE 1;:TRIGGER:ENHANCED:SPIBUS:
DATA1:BYTE 1;CONDITION TRUE;
DPOSITION 1;PATTERN1 "00010010";
PATTERN2 "00110100";
PATTERN3 "01010110";
PATTERN4 "00010010";SOURCE 3;:TRIGGER:
ENHANCED:SPIBUS:DATA2:BYTE 4;
CONDITION TRUE;DPOSITION 1;
PATTERN1 "00010010";
PATTERN2 "00110100";
PATTERN3 "01010110";
PATTERN4 "00010010";SOURCE 3;:TRIGGER:
ENHANCED:SPIBUS:MODE WIRE3
:TRIGger:ENHanced:SPIBus:BITorder
Function Sets the bit order of the SPI bus trigger or queries the
current setting.
Syntax
:TRIGger:ENHanced:SPIBus:
BITorder {LSBFirst|MSBFirst}
:TRIGger:ENHanced:SPIBus:BITorder?
Example
:TRIGGER:ENHANCED:SPIBUS:
BITORDER LSBFIRST
:TRIGGER:ENHANCED:SPIBUS:BITORDER?
-> :TRIGGER:ENHANCED:SPIBUS:
BITORDER LSBFIRST
:TRIGger:ENHanced:SPIBus:CLOCk?
Function Queries all settings related to the clock of the SPI bus
trigger.
Syntax
:TRIGger:ENHanced:SPIBus:CLOCk?
Example
:TRIGGER:ENHANCED:SPIBUS:CLOCK?
-> :TRIGGER:ENHANCED:SPIBUS:CLOCK:
POLARITY FALL;SOURCE 1
:TRIGger:ENHanced:SPIBus:CLOCk:
POLarity
Function Sets the polarity of the clock trace of the SPI bus
trigger or queries the current setting.
Syntax
:TRIGger:ENHanced:SPIBus:CLOCk:
POLarity {FALL|RISE}
:TRIGger:ENHanced:SPIBus:CLOCk:
POLarity?
Example
:TRIGGER:ENHANCED:SPIBUS:CLOCK:
POLARITY FALL
:TRIGGER:ENHANCED:SPIBUS:CLOCK:
POLARITY? -> :TRIGGER:ENHANCED:SPIBUS:
CLOCK:POLARITY FALL
5.29 TRIGger Group

Table of Contents