5-45
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:ANALysis:FFT<x>:MEASure:MARKer?
Function Queries all settings related to the marker cursor
measurement of the FFT computation.
Syntax
:ANALysis:FFT<x>:MEASure:MARKer?
<x> = 1 or 2
Example
:ANALYSIS:FFT1:MEASURE:MARKER?
-> :ANALYSIS:FFT1:MEASURE:MARKer:BASIC:
DFREQUENCY:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
DV:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
FREQUENCY1:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
FREQUENCY2:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
POSITION1 1.000E+00;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
POSITION2 2.000E+00;V1:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
V2:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:
CALCULATION:DEFINE1 "V(F1)";DEFINE2
"V(F2)";DEFINE3 "V(F1)";DEFINE4
"V(F2)";STATE1 1;STATE2 1;STATE3
1;STATE4 1
:ANALysis:FFT<x>:MEASure:
MARKer:BASic?
Function Queries all settings related to basic items of the
marker cursor of the FFT computation.
Syntax
:ANALysis:FFT<x>:MEASure:
MARKer:BASic?
<x> = 1 or 2
Example
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC?
-> :ANALYSIS:FFT1:MEASURE:MARKer:BASIC:
DFREQUENCY:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:
BASIC:DV:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
FREQUENCY1:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
FREQUENCY2:STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:
BASIC:POSITION1 1.000E+00;
:ANALYSIS:FFT1:MEASURE:
MARKER:BASIC:POSITION2 2.000E+00;V1:
STATE 1;
:ANALYSIS:FFT1:MEASURE:MARKER:
BASIC:V2:STATE 1
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:ALL
Function Turns ON/OFF all basic items of the marker cursor of
the FFT computation.
Syntax
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:ALL {<Boolean>}
<x> = 1 or 2
Example
:ANALYSIS:FFT1:MEASURE:MARKER:BASIC:
ALL ON
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:DFRequency?
Function Queries all settings related to the frequency value
between marker cursors of the FFT computation.
Syntax
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:DFRequency?
<x> = 1 or 2
Example
:ANALYSIS:FFT1:MEASURE:MARKer:BASIC:
DFREQUENCY? -> :ANALYSIS:FFT1:MEASURE:
MARKer:BASIC:DFREQUENCY:STATE 1
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:DFRequency:STATe
Function Turns ON/OFF the frequency value between marker
cursors of the FFT computation or queries the current
setting.
Syntax
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:DFRequency:
STATe {<Boolean>}
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:DFRequency:STATe?
<x> = 1 or 2
Example
:ANALYSIS:FFT1:MEASURE:MARKer:BASIC:
DFREQUENCY:STATE ON
:ANALYSIS:FFT1:MEASURE:MARKer:BASIC:
DFREQUENCY:STATE?
->:ANALYSIS:FFT1:MEASURE:MARKer:
BASIC:DFREQUENCY:STATE 1
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:DFRequency:VALue?
Function Queries the frequency value between marker cursors
of the FFT computation.
Syntax
:ANALysis:FFT<x>:MEASure:
MARKer[:BASic]:DFRequency:VALue?
<x> = 1 or 2
Example
:ANALYSIS:FFT1:MEASURE:MARKer:BASIC:
DFREQUENCY:VALUE? -> :ANALYSIS:FFT1:
MEASURE:MARKer:BASIC:
DFREQUENCY:VALUE 1.000E+00
5.3 ANALysis Group