:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:ALL
Function Turns ON/OFF all histogram cursors of waveform
parameter measurement.
Syntax
:ANALysis:WPARameter<x>HISTogram:
MEASure:CURSor:ALL {<Boolean>}
<x> = 1 or 2
Example
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:ALL ON
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:C<x>?
Function Queries all settings related to the cursor
measurement on the histogram of the waveform
parameter measurement.
Syntax
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:C<x>?
<x> of WPARameter<x> = 1 or 2
<x> of C<x> = 1 or 2
Example
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1:POSITION 1.000E+00;
STATE 1
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:C<x>:POSition
Function Sets the cursor position on the trend of the waveform
parameter measurement or queries the current
setting.
Syntax
:ANALysis:WPARameter<x>:HISTogram:
MEASure:PARameter:C<x>:POSition {<NRf>}
:ANALysis:WPARameter<x>:HISTogram:
MEASure:PARameter:C<x>:POSition?
<x> of WPARameter<x> = 1 or 2
<x> of C<x> = 1 or 2
<NRf> = –5 to 5 (div)
Example
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1:POSITION ON
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1:POSITION?
-> :ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1:POSITION 1.000E+00
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:C<x>:STATe
Function Turns ON/OFF the cursor on the histogram of the
waveform parameter measurement or queries the
current setting.
Syntax
:ANALysis:WPARameter<x>:HISTogram:
MEASure:PARameter:C<x>:
STATe {<Boolean>}
:ANALysis:WPARameter<x>:HISTogram:
MEASure:PARameter:C<x>:STATe?
<x> of WPARameter<x> = 1 or 2
<x> of C<x> = 1 or 2
Example
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1:STATE ON
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1:STATE? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM:MEASURE:CURSOR:
C1:STATE 1
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:C<x>:VALue?
Function Queries the measured value of the cursor on the
histogram of the waveform parameter measurement.
Syntax
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:C<x>:VALue?
<x> of WPARameter<x> = 1 or 2
<x> of C<x> = 1 or 2
Example
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:C1:VALUE? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM:MEASURE:CURSOR:
C1:VALUE 1.000E+00
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:DC?
Function Queries all settings related to the measurement
between cursors on the histogram of the waveform
parameter measurement.
Syntax
:ANALysis:WPARameter<x>:HISTogram:
MEASure:CURSor:DC?
<x> = 1 or 2
Example
:ANALYSIS:WPARAMETER1:HISTOGRAM:
MEASURE:CURSOR:DC? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM:MEASURE:CURSOR:
DC:STATE 1
5.3 ANALysis Group

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL9040 and is the answer not in the manual?

YOKOGAWA DL9040 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL9040
CategoryTest Equipment
LanguageEnglish

Related product manuals