5-74
IM 710105-17E
:ANALysis:PMEAsure<x>:USER<y>:STATe
Function Sets or queries the on/off status of automated
measurement of a Calc item.
Syntax
:ANALysis:PMEAsure<x>:USER<y>:STA
Te {<Boolean>}
:ANALysis:PMEAsure<x>:USER<y>:STATe?
<x> = 1 to 2
<y> = 1 to 4
Example
:ANALYSIS:PMEASURE:USER:STATE ON
:ANALYSIS:PMEASURE:USER:STATE?
-> :ANALYSIS:PMEASURE:USER:STATE 1
:ANALysis:PMEAsure<x>:USER<y>:UNIT
Function Sets or queries the unit of a Calc item.
Syntax
:ANALysis:PMEAsure<x>:USER<y>:UN
IT {<String>}
:ANALysis:PMEAsure<x>:USER<y>:UNIT?
<x> = 1 to 2
<y> = 1 to 4
<String> = Up to 4 characters
Example
:ANALYSIS:PMEASURE:USER:UNIT "ABC"
:ANALYSIS:PMEASURE:USER:UNIT?
-> :ANALYSIS:PMEASURE:USER:UNIT "ABC"
:ANALysis:PMEAsure<x>:USER<y>:VALue?
Function Queries the automatically measured value of a
Calc item.
Syntax
:ANALysis:PMEAsure<x>:USER<y>:VAL
ue? {<NRf>}
<x> = 1 to 2
<y> = 1 to 4
<NRf> = 1 to 100000
Example
:ANALYSIS:PMEASURE:USER:VALUE?
-> :ANALYSIS:PMEASURE:USER:VALUE 0.0
Description If the value is immeasurable, the DLM2000
returns “NAN” (not a number).
The <NRf> is used to specify which iteration of
automated measurement to query the measured
value from.
If <NRf> is set to 1, the oldest measured value
in the automated measurement memory is
queried.
If a measured value does not exist at the
specified iteration, the DLM2000 returns “NAN”
(not a number).
If <NRf> is omitted, the most recent measured
value is queried.
:ANALysis:WAIT?
Function Waits for the completion of automated
measurement with a set timeout.
Syntax
:ANALysis:WAIT? {<NRf>}
<NRf> = 1 to 36000 (the timeout specified in 100
ms intervals)
Example
:ANALYSIS:WAIT?
-> :ANALYSIS:WAIT 1
Description The command returns zero if the automated
measurement finishes within the specified
timeout. If automated measurement does not
finish, or if it was never taking place to begin with,
the command returns 1. Even if you set a long
timeout, the command will return zero as soon as
automated measurement finishes.
5.3 ANALysis Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM2000 Series and is the answer not in the manual?

YOKOGAWA DLM2000 Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals