5-55
IM 710105-17E
Commands
1
2
3
4
5
6
App
Index
:ACQuire:RESolution
Function Sets or queries the on/off status of High Resolution
mode.
Syntax
:ACQuire:RESolution {<Boolean>}
Example
:ACQUIRE:RESOLUTION ON
:ACQUIRE:RESOLUTION?
-> :ACQUIRE:RESOLUTION 1
Description The maximum record length is reduced to half
when High Resolution mode is turned on.
:ACQuire:RLENgth
Function Sets or queries the record length.
Syntax
:ACQuire:RLENgth {<NRf>}
<NRf> = See the DLM2000 Features Guide for
this information.
Example
:ACQUIRE:RLENGTH 1250
:ACQUIRE:RLENGTH?
-> :ACQUIRE:RLENGTH 1250
:ACQuire:SAMPling
Function Sets or queries the sampling mode.
Syntax
:ACQuire:SAMPling {REAL|INTerporate|
REPetitive}
Example
:ACQUIRE:SAMPLING REAL
:ACQUIRE:SAMPLING?
-> :ACQUIRE:SAMPLING REAL
5.2 ACQuire Group
:ACQuire?
Function Queries all waveform acquisition settings.
Syntax
:ACQuire?
:ACQuire:AVERage?
Function Queries all of the settings related to averaging and
the number of waveform acquisitions.
Syntax
:ACQuire:AVERage?
:ACQuire:AVERage:COUNt
Function Sets or queries the attenuation constant for
exponential averaging or the average count for
linear averaging for Averaging mode.
Syntax
:ACQuire:AVERage:COUNt {<NRf>}
<NRf> = 2 to 1024 in 2
n
steps)
Example
:ACQUIRE:AVERAGE:COUNT 2
:ACQUIRE:AVERAGE:COUNT?
-> :ACQUIRE:AVERAGE:COUNT 2
:ACQuire:COUNt
Function Sets or queries the number of waveform
acquisitions in Normal, Envelope, and Averaging
modes.
Syntax
:ACQuire:COUNt {<NRf>|INFinity}
<NRf> = 1 to 65536
Example
:ACQUIRE:COUNT 1
:ACQUIRE:COUNT?
-> :ACQUIRE:COUNT 1
:ACQuire:INTerleave
Function Sets or queries the on/off status of Interleave
mode.
Syntax
:ACQuire:INTerleave {<Boolean>}
Example
:ACQUIRE:INTERLEAVE ON
:ACQUIRE:INTERLEAVE?
-> :ACQUIRE:INTERLEAVE 1
:ACQuire:MODE
Function Sets or queries the waveform acquisition mode.
Syntax
:ACQuire:MODE {AVERage|ENVelope|
NORMal}
Example
:ACQUIRE:MODE AVERAGE
:ACQUIRE:MODE?
-> :ACQUIRE:MODE AVERAGE

Table of Contents