Page #225 background imageLoading...
Page #225 background image
5-192
IM 710105-17E
:SERialbus<x>:PSI5:SEARch:SETup:ERRo
r:PCRC
Function Sets or queries the PSI5 signal parity/CRC error
search.
Syntax
:SERialbus<x>:PSI5:SEARch:SETup:ERRor
:PCRC {<Boolean>}
:SERialbus<x>:PSI5:SEARch:SETup:ERRor
:PCRC?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:P
CRC ON
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:P
CRC?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:ERRO
R:PCRC 1
:SERialbus<x>:PSI5:SEARch:SETup:ERRo
r:SBIT
Function Sets or queries the PSI5 signal start bit error
search.
Syntax
:SERialbus<x>:PSI5:SEARch:SETup:ERRor
:SBIT {<Boolean>}
:SERialbus<x>:PSI5:SEARch:SETup:ERRor
:SBIT?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:S
BIT ON
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:S
BIT?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:ERRO
R:SBIT 1
:SERialbus<x>:PSI5:SEARch:SETup:ERRo
r:SBOundary
Function Sets or queries the PSI5 signal slot boundary error
search.
Syntax
:SERialbus<x>:PSI5:SEARch:SETup:ERRor
:SBOundary {<Boolean>}
:SERialbus<x>:PSI5:SEARch:SETup:ERRor
:SBOundary?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:S
BOUNDARY ON
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:S
BOUNDARY?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:ERRO
R:SBOUNDARY 1
:SERialbus<x>:PSI5:SEARch:SETup:FRAM
einslot?
Function Queries all PSI5 signal slot specification search
settings.
Syntax
:SERialbus<x>:PSI5:SEARch:SETup:FRAMe
inslot?
<x> = 1 to 4
:SERialbus<x>:PSI5:SEARch:SETup:FRAM
einslot:SNUMber
Function Sets or queries the slot number of the PSI5 signal
slot specification search.
Syntax
:SERialbus<x>:PSI5:SEARch:SETup:FRAMe
inslot:SNUMber {<NRf>}
:SERialbus<x>:PSI5:SEARch:SETup:FRAMe
inslot:SNUMber?
<x> = 1 to 4
<NRf> = 1 to 6
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:FRAMEIN
SLOT:SNUMBER 1
:SERIALBUS1:PSI5:SEARCH:SETUP:FRAMEIN
SLOT:SNUMBER?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:FRAM
EINSLOT:SNUMBER 1
:SERialbus<x>:PSI5:SEARch:SETup:MODE
Function Sets or queries the PSI5 signal search mode
setting.
Syntax
:SERialbus<x>:PSI5:SEARch:SETup:MO
DE {DATA|ERRor|FRAMeinslot|SBIT|SYNC}
:SERialbus<x>:PSI5:SEARch:SETup:MODE?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:MO
DE DATA
:SERIALBUS1:PSI5:SEARCH:SETUP:MODE?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:MO
DE DATA
:SERialbus<x>:PSI5:TRENd<y>?
Function Queries all PSI5 signal analysis trend display
settings.
Syntax
:SERialbus<x>:PSI5:TRENd<y>?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:PSI5:TRENd<y>:ASCale
Function Executes auto scaling of the PSI5 signal analysis
trend display.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:ASCale
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:PSI5:TREND1:ASCALE
:SERialbus<x>:PSI5:TRENd<y>:CURSor?
Function Queries all PSI5 signal analysis trend display
cursor measurement settings.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:CURSor?
<x> = 1 to 4
<y> = 1 to 4
5.24 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series