5-207
IM 710105-17E
Commands
5
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID?
Function Queries all slow channel short type ID settings for
SENT signal searching.
Syntax
:SERialbus<x>:SENT:SEARch:[SETup]:SDA
Ta:SHORt:ID?
<x> = 1 to 4
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:CONDition
Function Sets or queries the short type ID comparison
condition of the SENT signal search slow channel.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:
SDATa:SHORt:ID:CONDition {BETWeen|EQU
al|GREater|LESS|NOTBetween|NOTEqul}
:SERialbus<x>:SENT:SEARch[:SETup]:
SDATa:SHORt:ID:CONDition?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:S
HORT:ID:CONDITION BETWEEN
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:S
HORT:ID:CONDITION?
-> :SERIALBUS1:SENT:SEARCH:SETUP:SDAT
A:SHORT:ID:CONDITION BETWEEN
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:DECimal<y>
Function Sets the SENT signal search slow channel short
type ID in decimal notation.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:SDA
Ta:SHORt:ID:DECimal<y> {<NRf>}
:SERialbus<x>:SENT:SEARch[:SETup]:SDA
Ta:SHORt:ID:DECimal<y>?
<x> = 1 to 4
<y> = 1 or 2
Example
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:S
HORT:ID:DECimal1 0
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:S
HORT:ID:DECIMAL1?
-> :SERIALBUS1:SENT:SEARCH:SETUP:SDAT
A:SHORT:ID:DECIMAL1 0
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:MODE
Function Sets or queries the short type ID enable/disable
condition of the SENT signal search slow channel.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:SDA
Ta:SHORt:ID:MODE {<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:SDA
Ta:SHORt:ID:MODE?
<x> =
1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:S
HORT:ID:MODE ON
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:S
HORT:ID:MODE?
-> :SERIALBUS1:SENT:SEARCH:SETUP:SDAT
A:SHORT:ID:MODE 1
:SERialbus<x>:SENT:TRENd<y>?
Function Queries all SENT signal analysis trend display
settings.
Syntax
:SERialbus<x>:SENT:TRENd<y>?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:ASCale
Function Executes auto scaling of the SENT signal analysis
trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:ASCale
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:TREND1:ASCALE
:SERialbus<x>:SENT:TRENd<y>:CURSor?
Function Queries all SENT signal analysis trend display
cursor measurement settings.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:CURSor:D
T:VALue?
Function Queries the time value between cursors on the
SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor:DT
:VALue?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:CURSor:D
V:VALue?
Function Queries the vertical value between cursors on the
SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor:DV
:VALue?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:CURSor:M
ODE
Function Sets or queries the automated measurement
mode of the SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor:MO
DE {<Boolean>}
:SERialbus<x>:SENT:TRENd<y>:CURSor:MO
DE?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:TREND1:CURSOR:MO
DE ON
:SERIALBUS1:SENT:TREND1:CURSOR:MODE?
-> :SERIALBUS1:SENT:TREND1:CURSOR:MO
DE 1
5.24 SERialbus Group