EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 275

YOKOGAWA DLM2000 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-242
IM 710105-17E
:TRIGger{[:ATRigger]|:BTRigger}:FLEX
ray[:IDData]:CCOunt:COUNt<x>
Function Sets or queries the cycle count, which is one of
the ID and data conditions, for FLEXRAY bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:CCOunt:COUNt<x> {<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:CCOunt:COUNt<x>?
<x> = 1 or 2
<NRf> = 0 to 63
Example
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:CCOU
NT:COUNT1 1
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:CCOU
NT:COUNT1?
-> :TRIGGER:ATRIGGER:FLEXRAY:IDDATA:C
COUNT:COUNT1 1
Description • For :TRIGger{[:ATRigger]|:BTRigger}:
FLEXray[:IDData]:CCOunt:CONDition
EQUal|GREater|NOTEqul, set the cycle-count
setting using :TRIGger{[:ATRigger]|:BTRigger}:
FLEXray[:IDData]:CCOunt:COUNt1.
For :TRIGger{[:ATRigger]|:BTRigger}:FLEXray[:I
DData]:CCOunt:CONDition LESS, set the cycle-
count setting using :TRIGger{[:ATRigger]|:BTRi
gger}:FLEXray[:IDData]:CCOunt:COUNt2.
For :TRIGger{[:ATRigger]|:BTRigger}:
FLEXray[:IDData]:CCOunt:CONDition
BETWeen|NOTBetween, set the smaller value
using :TRIGger{[:ATRigger]|:BTRigger}:FLEXra
y[:IDData]:CCOunt:COUNt1, and set the larger
value using :TRIGger{[:ATRigger]|:BTRigger}:F
LEXray[:IDData]:CCOunt:COUNt2.
:TRIGger{[:ATRigger]|:BTRigger}:FLEX
ray[:IDData]:CCOunt:MODE
Function Sets or queries the cycle-count enable/disable
condition, which is one of the ID and data
conditions, for FLEXRAY bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:CCOunt:MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:CCOunt:MODE?
Example
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:CCOU
NT:MODE ON
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:CCOU
NT:MODE?
-> :TRIGGER:ATRIGGER:FLEXRAY:IDDATA:C
COUNT:MODE 1
:TRIGger{[:ATRigger]|:BTRigger}:FLEX
ray[:IDData]:DATA<x>?
Function Queries all data field settings for the ID and data
conditions for FLEXRAY bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:DATA<x>?
<x> = 1 or 2
:TRIGger{[:ATRigger]|:BTRigger}:FLEX
ray[:IDData]:DATA<x>:BCOunt
Function Sets or queries the position for comparing data
field data patterns, which is one of the ID and data
conditions, for FLEXRAY bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:DATA<x>:BCOunt {<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:DATA<x>:BCOunt?
<x> = 1 or 2
<NRf> = 0 to 253
Example
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:DATA
1:BCOUNT 1
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:DATA
1:BCOUNT?
-> :TRIGGER:ATRIGGER:FLEXRAY:IDDATA:D
ATA1:BCOUNT 1
:TRIGger{[:ATRigger]|:BTRigger}:FLEX
ray[:IDData]:DATA<x>:CONDition
Function Sets or queries the data field data condition, which
is one of the ID and data conditions, for FLEXRAY
bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:DATA<x>:CONDition {BETWee
n|EQUal|FALSe|GREater|LESS|NOTBetween
|NOTEqul|TRUE}
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:DATA<x>:CONDition?
<x> = 1 or 2
Example
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:DATA
1:CONDITION BETWEEN
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:DATA
1:CONDITION?
-> :TRIGGER:ATRIGGER:FLEXRAY:IDDATA:D
ATA1:CONDITION BETWEEN
:TRIGger{[:ATRigger]|:BTRigger}:FLEX
ray[:IDData]:DATA<x>:DBYTe
Function Sets or queries the number of data field data
bytes, which is one of the ID and data conditions,
for FLEXRAY bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:DATA<x>:DBYTe {<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:FLEXr
ay[:IDData]:DATA<x>:DBYTe?
<x> = 1 or 2
<NRf> = 1 to 8
Example
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:DATA
1:DBYTE 1
:TRIGGER:ATRIGGER:FLEXRAY:IDDATA:DATA
1:DBYTE?
-> :TRIGGER:ATRIGGER:FLEXRAY:IDDATA:D
ATA1:DBYTE 1
5.33 TRIGger Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Related product manuals