5-254
IM 710105-17E
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:DATA:MSBLsb
Function Sets or queries the data MSB and LSB bits for LIN
bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:MSBLsb {<NRf>,<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:MSBLsb?
<NRf>,<NRf> = 0 to 63
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:MSB
LSB 0
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:MSB
LSB?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:DATA:
MSBLSB 0
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:DATA:PATTern<x>
Function Sets or queries the data value for LIN bus signal
triggering in binary notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:PATTern<x> {<String>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:PATTern<x>?
<x> = 1 to 8
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:PAT
TERN1 "00110101"
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:PAT
TERN1?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:DATA:
PATTERN1 "00110101"
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:DATA:PFORmat
Function Sets or queries the input format, which is one of
the data conditions, for LIN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:PFORmat {BINary|HEXa}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:PFORmat?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:PFO
RMAT BINARY
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:PFO
RMAT?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:DATA:
PFORMAT BINARY
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:DATA:SIGN
Function Sets or queries whether signed or unsigned data
format will be used, which is one of the data
conditions, for LIN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:SIGN {SIGN|UNSign}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:DATA:SIGN?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:SI
GN SIGN
:TRIGGER:ATRIGGER:LIN:IDDATA:DATA:SI
GN?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:DATA:
SIGN SIGN
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier?
Function Queries all LIN bus signal trigger identifier
settings.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:IDENtifier?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID?
Function Queries all LIN bus signal trigger ID settings.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:IDENtifier:ID?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:HEXa
Function Sets the ID for LIN bus signal triggering in
hexadecimal notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:IDENtifier:ID:HEXa {<String>}
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIFI
ER:ID:HEXA "1E"
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:MODE
Function Sets or queries the ID enable/disable condition,
which is one of the ID and data conditions, for LIN
bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:IDENtifier:ID:MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:I
DData:IDENtifier:ID:MODE?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIFI
ER:ID:MODE ON
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIFI
ER:ID:MODE?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:IDENT
IFIER:ID:MODE 1