EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 90

YOKOGAWA DLM2000 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-57
IM 710105-17E
Commands
1
2
3
4
5
6
App
Index
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:<Parameter>:STATe
Function Sets or queries the on/off status of the specified
measurement item of a waveform histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:<Parameter>:STATe {<Boolean>}
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:<Parameter>:STATe?
<x> = 1 or 2 (1 only for 2-channel models)
<Parameter> = {
C1|C2|DC|MAXimum|MEAN|
MEDian|MINimum|PEAK|SD2integ|
SD3integ|SDEViation|SDINteg
}
Example (Below are examples for the maximum value.)
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:MAXIMUM:STATE ON
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:MAXIMUM:STATE?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:MAXIMUM:STATE 1
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:<Parameter>:VALue?
Function Queries the automatically measured value for
the specified measurement item of a waveform
histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:<Parameter>:VALue?
<x> = 1 or 2 (1 only for 2-channel models)
<Parameter> = {
C1|C2|DC|MAXimum|MEAN|
MEDian|MINimum|PEAK|SD2integ|
SD3integ|SDEViation|SDINteg
}
Example (Below are examples for the maximum value.)
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:MAXIMUM:VALUE?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:MAXIMUM:VALUE 1.000E+00
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:HPOSition<y>
Function Sets or queries the horizontal position of Cursor1
or Cursor 2 for a waveform histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:HPOSition<y> {<NRf>}
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:HPOSition<y>?
<x> = 1 or 2 (1 only for 2-channel models)
<y> = 1 or 2
<NRf>=−5to5(divisions)
Example
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:HPOSITION1 1
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:HPOSITION1?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:HPOSITION 1.000E+00
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:VPOSition<y>
Function Sets or queries the vertical position of Cursor1 or
Cursor 2 for a waveform histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:VPOSition<y> {<NRf>}
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:VPOSition<y>?
<x> = 1 or 2 (1 only for 2-channel models)
<y> = 1 or 2
<NRf>=−4to4(divisions)
Example
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:VPOSITION1 1
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:VPOSITION1?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:VPOSITION 1.000E+00
5.3 ANALysis Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Related product manuals