Page #90 background imageLoading...
Page #90 background image
5-57
IM 710105-17E
Commands
1
2
3
4
5
6
App
Index
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:<Parameter>:STATe
Function Sets or queries the on/off status of the specified
measurement item of a waveform histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:<Parameter>:STATe {<Boolean>}
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:<Parameter>:STATe?
<x> = 1 or 2 (1 only for 2-channel models)
<Parameter> = {
C1|C2|DC|MAXimum|MEAN|
MEDian|MINimum|PEAK|SD2integ|
SD3integ|SDEViation|SDINteg
}
Example (Below are examples for the maximum value.)
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:MAXIMUM:STATE ON
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:MAXIMUM:STATE?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:MAXIMUM:STATE 1
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:<Parameter>:VALue?
Function Queries the automatically measured value for
the specified measurement item of a waveform
histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:<Parameter>:VALue?
<x> = 1 or 2 (1 only for 2-channel models)
<Parameter> = {
C1|C2|DC|MAXimum|MEAN|
MEDian|MINimum|PEAK|SD2integ|
SD3integ|SDEViation|SDINteg
}
Example (Below are examples for the maximum value.)
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:MAXIMUM:VALUE?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:MAXIMUM:VALUE 1.000E+00
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:HPOSition<y>
Function Sets or queries the horizontal position of Cursor1
or Cursor 2 for a waveform histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:HPOSition<y> {<NRf>}
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:HPOSition<y>?
<x> = 1 or 2 (1 only for 2-channel models)
<y> = 1 or 2
<NRf>=−5to5(divisions)
Example
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:HPOSITION1 1
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:HPOSITION1?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:HPOSITION 1.000E+00
:ANALysis:AHIStogram<x>:MEASure:PARa
meter:VPOSition<y>
Function Sets or queries the vertical position of Cursor1 or
Cursor 2 for a waveform histogram.
Syntax
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:VPOSition<y> {<NRf>}
:ANALysis:AHIStogram<x>:MEASure:PARam
eter:VPOSition<y>?
<x> = 1 or 2 (1 only for 2-channel models)
<y> = 1 or 2
<NRf>=−4to4(divisions)
Example
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:VPOSITION1 1
:ANALYSIS:AHISTOGRAM1:MEASURE:PARAMET
ER:VPOSITION1?
-> :ANALYSIS:AHISTOGRAM1:MEASURE:PARA
METER:VPOSITION 1.000E+00
5.3 ANALysis Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM2000 Series and is the answer not in the manual?

YOKOGAWA DLM2000 Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals