5-63
IM 710105-17E
Commands
1
2
3
4
5
6
App
Index
:ANALysis:PANalyze<x>:SETup:U?
Function Queries all voltage input channel settings for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U?
<x> = 1 or 2
:ANALysis:PANalyze<x>:SETup:U:DESKew
Function Sets or queries the deskew setting of the voltage
input channel for power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U:DESK
ew {<Time>}
:ANALysis:PANalyze<x>:SETup:U:DESKew?
<x> = 1 or 2
<Time>=−100.0nsto100.0ns(in10-pssteps)
Example
:ANALYSIS:PANALYZE1:SETUP:U:DESK
EW 1NS
:ANALYSIS:PANALYZE1:SETUP:U:DESKEW?
-> :ANALYSIS:PANALYZE1:SETUP:U:DESK
EW1.000E−09
:ANALysis:PANalyze<x>:SETup:U:INPut
Function Sets or queries the voltage input channel for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U:INP
ut {1|3}
:ANALysis:PANalyze<x>:SETup:U:INPut?
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SETUP:U:INPUT 1
:ANALYSIS:PANALYZE1:SETUP:U:INPUT?
-> :ANALYSIS:PANALYZE1:SETUP:U:
INPUT 1
:ANALysis:PANalyze<x>:SETup:U:PROBe
Function Sets or queries the probe attenuation setting of the
voltage input channel for power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U:PRO
Be {<NRf>}
:ANALysis:PANalyze<x>:SETup:U:PROBe?
<x> = 1 or 2
<NRf> = See the DLM2000 Features Guide for
this information.
Example
:ANALYSIS:PANALYZE1:SETUP:U:PROBE 1
:ANALYSIS:PANALYZE1:SETUP:U:PROBE?
-> :ANALYSIS:PANALYZE1:SETUP:U:
PROBE 1.000
:ANALysis:PANalyze<x>:SETup:I?
Function Queries all current input channel settings for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:I?
<x> = 1 or 2
:ANALysis:PANalyze<x>:SETup:I:DESKew
Function Sets or queries the deskew setting of the current
input channel for power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:I:DESK
ew {<Time>}
:ANALysis:PANalyze<x>:SETup:I:DESKew?
<x> = 1 or 2
<Time>=−100.0nsto100.0ns(in10-pssteps)
Example
:ANALYSIS:PANALYZE1:SETUP:I:DESK
EW 1NS
:ANALYSIS:PANALYZE1:SETUP:I:DESKEW?
-> :ANALYSIS:PANALYZE1:SETUP:I:DESK
EW1.000E−09
:ANALysis:PANalyze<x>:SETup:I:INPut
Function Sets or queries the current input channel for power
supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:I:INP
ut {2|4}
:ANALysis:PANalyze<x>:SETup:I:INPut?
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SETUP:I:INPUT 2
:ANALYSIS:PANALYZE1:SETUP:I:INPUT?
-> :ANALYSIS:PANALYZE1:SETUP:I:
INPUT 2
:ANALysis:PANalyze<x>:SETup:I:PROBe
Function Queries all current-to-voltage conversion ratio
settings for the current input channel probe for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:I:PRO
Be {C0_001|C0_002|C0_005|C0_01|C0_02|
C0_05|C0_1|C0_2|C0_5|C1|C2|C5|C10|
C20|C50|C100|C200|C500|C1000|C2000}}
:ANALysis:PANalyze<x>:SETup:I:PROBe?
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SETUP:I:PROBE C0_
001
:ANALYSIS:PANALYZE1:SETUP:I:PROBE?
-> :ANALYSIS:PANALYZE1:SETUP:I:
PROBE C0_001
5.3 ANALysis Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series