App-11
IM DLM5058-03EN
Appendix
1
2
3
4
5
6
App
Index
When the Set Record Length Is 125 Mpoint
(This record length can be selected on all models)
Mode
Setting
High Resolution Mode OFF High Resolution Mode ON
RealTime Interpolation
*
Repetitive RealTime Interpolation
*
Repetitive
Time/div
Sample
Rate
(S/s)
Display
Record
Length
(Point)
Sample
Rate
(S/s)
Display
Record
Length
(Point)
Sample
Rate
(S/s)
Display
Record
Length
(Point)
Sample
Rate
(S/s)
Display
Record
Length
(Point)
Sample
Rate
(S/s)
Display
Record
Length
(Point)
Sample
Rate
(S/s)
Display
Record
Length
(Point)
500 s
25 k 125 M 25 k 125 M
Repetitive
sampling mode
cannot be used
with this record
length.
25 k 125 M 25 k 125 M
Repetitive
sampling mode
cannot be used
with this record
length.
200 s
62.5 k 125 M 62.5 k 125 M 62.5 k 125 M 62.5 k 125 M
100 s
125 k 125 M 125 k 125 M 125 k 125 M 125 k 125 M
50 s
250 k 125 M 250 k 125 M 250 k 125 M 250 k 125 M
20 s
625 k 125 M 625 k 125 M 625 k 125 M 625 k 125 M
10 s
1.25 M 125 M 1.25 M 125 M 1.25 M 125 M 1.25 M 125 M
5 s
2.5 M 125 M 2.5 M 125 M 2.5 M 125 M 2.5 M 125 M
2 s
6.25 M 125 M 6.25 M 125 M 6.25 M 125 M 6.25 M 125 M
1 s
12.5 M 125 M 12.5 M 125 M 12.5 M 125 M 12.5 M 125 M
500 ms
25 M 125 M 25 M 125 M 25 M 125 M 25 M 125 M
200 ms
62.5 M 125 M 62.5 M 125 M 62.5 M 125 M 62.5 M 125 M
100 ms
125 M 125 M 125 M 125 M 125 M 125 M 125 M 125 M
50 ms
250 M 125 M 250 M 125 M 250 M 125 M 250 M 125 M
20 ms
625 M 125 M 625 M 125 M 625 M 125 M 625 M 125 M
10 ms
1.25 G 125 M 1.25 G 125 M 1.25 G 125 M 1.25 G 125 M
5 ms
2.5 G 125 M 2.5 G 125 M 1.25 G 62.5 M 2.5 G 125 M
2 ms
2.5 G 50 M 5 G 100 M 1.25 G 25 M 5 G 100 M
1 ms
2.5 G 25 M 12.5 G 125 M 1.25 G 12.5 M 12.5 G 125 M
500 µs
2.5 G 12.5 M 25 G 125 M 1.25 G 6.25 M 25 G 125 M
200 µs
2.5 G 5 M 62.5 G 125 M 1.25 G 2.5 M 62.5 G 125 M
100 µs
2.5 G 2.5 M 125 G 125 M 1.25 G 1.25 M 125 G 125 M
50 µs
2.5 G 1.25 M 250 G 125 M 1.25 G 625 k 250 G 125 M
20 µs
2.5 G 500 k 250 G 50 M 1.25 G 250 k 250 G 50 M
10 µs
2.5 G 250 k 250 G 25 M 1.25 G 125 k 250 G 25 M
5 µs
2.5 G 125 k 250 G 12.5 M 1.25 G 62.5 k 250 G 12.5 M
2 µs
2.5 G 50 k 250 G 5 M 1.25 G 25 k 250 G 5 M
1 µs
2.5 G 25 k 250 G 2.5 M 1.25 G 12.5 k 250 G 2.5 M
500 ns
2.5 G 12.5 k 250 G 1.25 M 1.25 G 6.25 k 250 G 1.25 M
200 ns
2.5 G 5 k 250 G 500 k 1.25 G 2.5 k 250 G 500 k
100 ns
2.5 G 2.5 k 250 G 250 k 1.25 G 1.25 k 250 G 250 k
50 ns
2.5 G 1.25 k 250 G 125 k 1.25 G 625 250 G 125 k
20 ns
2.5 G 500 250 G 50 k 1.25 G 250 250 G 50 k
10 ns
2.5 G 250 250 G 25 k 1.25 G 125 250 G 25 k
5 ns
2.5 G 125 250 G 12.5 k 1.25 G 62.5 250 G 12.5 k
2 ns
2.5 G 50 250 G 5 k 1.25 G 25 250 G 5 k
1 ns
2.5 G 25 250 G 2.5 k 1.25 G 12.5 250 G 2.5 k
Values outside of the thick borders have been calculated in real-time sampling mode.
Acquisition when you specify this record length is performed in single mode.
* If there is no memory option or with the /M1S or /M1 option, interpolation mode cannot be used with this record length.
: Roll mode
Appendix 1 Relationship between the Time Axis Setting, Sample Rate, and Record Length

Table of Contents

Other manuals for YOKOGAWA DLM5034

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM5034 and is the answer not in the manual?

YOKOGAWA DLM5034 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM5034
CategoryTest Equipment
LanguageEnglish

Related product manuals