7.2 Parameters – Multi
Temperature Version
7.2 Parameters – Multi Temperature Version
Regulation Parameters Table
Label Description Udm Value
dF1
1st Diesel intervention Differential
°C °F
2
4
dF2
1st Stand-by intervention Differential
°C °F
3
5
ddF
Engine speed Differential
°C °F
1
2
min
Lower temperature set-point limit
°C °F
-30
-22
MAS
Higher temperature set-point limit
°C °F
25
77
Evp
Evaporators number -
2/3
Adr2
2nd Evaporator net address
°C °F
1
Adr3
3rd Evaporator net address
°C °F
2
Min2
2nd Evaporator minimum temperature setpoint
°C °F
-30
MAS2
2nd Evaporator Maximum temperature setpoint
°C °F
25
77
Min3
3rd Evaporator minimum temperature setpoint
°C °F
-30
-22
MAS3
3rd Evaporator Maximum temperature setpoint
°C °F
25
77
tAP
After Start GlowPlug Active Time
sec
3
3
tgv
Condenser fans start delay
sec
3
3
Sac
Low speed with compressor reduced capacity
sec
0
Defrost Parameter Table
Label Description
Ud
m
Val
ue
tEb
Temperature alarm cut out time after defrost min 60
tMS
Maximum defrosting time min 15
tPS
End defrost detection type - air switch
tGo
Draining time min 0
tSS
Time between defrost operations min 120
btS
Temperature detection stop during defrost - OFF
Svb
Evaporator fans state during defrost - OFF
trE
Evaporator fans activation delay after defrost min 1
Svb2
2nd Evaporator fans state during defrost - OFF
Svb3
3rd Evaporator fans state during defrost - OFF
tMS2
2nd Evaporator Maximum defrosting time min 15
tMS3
2nd Evaporator Maximum defrosting time min 15