74
Cooling Circuit
3.9 Sc
roll Stand-by
Compresso
r
Stand-by Compressor Replacement
(a)
Open unit top cover (Nose Mount) or open unit
f
ront door (Under Moun
t).
(b)
Open unit bottom cover.
(c)
Recover refrigerant 3.2.2 Section.
(d)
Close all of compressors Valves.
(e)
Disconnect Unit from Electrical
Supplies (Battery and Electri
c
al
Main).
(f)
Unscrew compressor base from
unit frame.
(g)
Extract/Pull out liquid injection
valve sensing bulb from
comp
ressor he
ad.
(h)
Unscrew, holding valve body, all of
scroll compressor Valves.
CAUT
ION
!
Do not disconnect
valves from fle
xible hoses.