EasyManuals Logo

Zapi ACE0 2mC User Manual

Zapi ACE0 2mC
155 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual Page – 65/155
SET OPTIONS
Parameter Allowable range Description
EVP2 TYPE
(A)
NONE ÷ DIGITAL This parameter defines the behavior of output EVP2 (A23).
NONE = Output A23 is not enabled.
ANALOG = Output A23 manages a PWM current-
controlled proportional valve.
DIGITAL = Output A23 manages an on/off valve.
EV1
(A)
ABSENT ÷ OPTION#2 This parameter defines the behavior of output EV1 (A9).
ABSENT = Output A9 is not enabled.
OPTION#1 = Output A9 manages an ON/OFF valve.
By default it is activated by the 1
st
speed command.
OPTION#2 = free for future use.
EV2
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV2 (A11).
ABSENT = Output A11 is not enabled.
DIGITAL = Output A11 manages a PWM voltage-
controlled valve. The PWM frequency is 1 kHz and the
duty cycle depends on parameter PWM EV2
(ADJUSTMENTS list, paragraph 8.2.3).
EV3
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV3 (A33).
ABSENT = Output A33 is not enabled.
DIGITAL = Output A33 manages a PWM voltage-
controlled valve. The PWM frequency is 1 kHz and the
duty cycle depends on parameter PWM EV3
(ADJUSTMENTS list, paragraph 8.2.3).
EV4
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV4 (A34).
ABSENT = Output A34 is not enabled.
DIGITAL = Output A34 manages an on/off valve.
EV5
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV5 (A8).
ABSENT = Output A8 is not enabled.
DIGITAL = Output A8 manages an on/off valve.
HORN
(A)
ABSENT ÷ DIGITAL It enables the control of output HORN (A26).
ABSENT = Output A26 is not enabled.
DIGITAL = Output A26 manages an ON/OFF valve.
HIGH DYNAMIC
(T, TM, P, CO)
OFF ÷ ON This parameter enables or disables the high-dynamic
function.
ON = All acceleration and deceleration profiles set by
dedicated parameters are ignored and the controller
works always with maximum performance.
OFF = Standard behavior.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi ACE0 2mC and is the answer not in the manual?

Zapi ACE0 2mC Specifications

General IconGeneral
BrandZapi
ModelACE0 2mC
CategoryInverter
LanguageEnglish

Related product manuals