AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual Page – 65/155
SET OPTIONS
Parameter Allowable range Description
EVP2 TYPE
(A)
NONE ÷ DIGITAL This parameter defines the behavior of output EVP2 (A23).
NONE = Output A23 is not enabled.
ANALOG = Output A23 manages a PWM current-
controlled proportional valve.
DIGITAL = Output A23 manages an on/off valve.
EV1
(A)
ABSENT ÷ OPTION#2 This parameter defines the behavior of output EV1 (A9).
ABSENT = Output A9 is not enabled.
OPTION#1 = Output A9 manages an ON/OFF valve.
By default it is activated by the 1
st
speed command.
OPTION#2 = free for future use.
EV2
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV2 (A11).
ABSENT = Output A11 is not enabled.
DIGITAL = Output A11 manages a PWM voltage-
controlled valve. The PWM frequency is 1 kHz and the
duty cycle depends on parameter PWM EV2
(ADJUSTMENTS list, paragraph 8.2.3).
EV3
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV3 (A33).
ABSENT = Output A33 is not enabled.
DIGITAL = Output A33 manages a PWM voltage-
controlled valve. The PWM frequency is 1 kHz and the
duty cycle depends on parameter PWM EV3
(ADJUSTMENTS list, paragraph 8.2.3).
EV4
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV4 (A34).
ABSENT = Output A34 is not enabled.
DIGITAL = Output A34 manages an on/off valve.
EV5
(A)
ABSENT ÷ DIGITAL This parameter defines the behavior of output EV5 (A8).
ABSENT = Output A8 is not enabled.
DIGITAL = Output A8 manages an on/off valve.
HORN
(A)
ABSENT ÷ DIGITAL It enables the control of output HORN (A26).
ABSENT = Output A26 is not enabled.
DIGITAL = Output A26 manages an ON/OFF valve.
HIGH DYNAMIC
(T, TM, P, CO)
OFF ÷ ON This parameter enables or disables the high-dynamic
function.
ON = All acceleration and deceleration profiles set by
dedicated parameters are ignored and the controller
works always with maximum performance.
OFF = Standard behavior.