EasyManua.ls Logo

Zetor 117 41 forterra turbo - Manoeuvring with Tractor and Reset of Temporary Memory; Temporary Memorising the PTO Speed

Zetor 117 41 forterra turbo
257 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
ELECTRONIC ENGINE GOVERNOR
RPM17
4. TEMPORARY MEMORISING THE
PTO SPEED
1. Press the keypad MAX. Indicator
lamp H/O turns on.
Since this the set engine speed cor-
responding the PTO speed 540 or 1000
RPM is entered in the temporary me-
mory. System will automatically maintain
the constant speed of PTO inde-
pendently upon load of tractor.
5. MANOEUVRING WITH TRACTOR
AND RESET OF TEMPORARY
MEMORY
1. Disengage the PTO shaft when ma-
noeuvring the tractor with implement.
2. Press the keypad MEM. Indicator
lamp H/O turns off.
Since this the temporary memory is
switched off and values entered in tem-
porary memory are definitively lost. The
engine works with speed corresponding
to travel speed set by keypads MIN or
MAX.

Table of Contents

Related product manuals