143
ELECTRIC INSTALLATION 
E603 
 E604 
ACCUMULATOR BATTERY 
The accumulator battery (1) is installed 
under the tractor cab on the left side.  
The battery disconnector is located at the 
left-hand side of the tractor at the battery.  
a -  Battery connected 
b -  Battery disconnected 
If the tractor is out of operation 
for a longer period of time, it is 
necessary to charge the battery 
at least once every three months 
due to its spontaneous discharg-
ing.  When you put the tractor out 
of operation, it is recommended 
to disconnect the battery with the 
disconnector.  
 
 
ACCUMULATOR BATTERY MAINTENANCE 
Keep the accumulator battery clean and properly fixed to the vehicle.  However, the 
fixing device must not deform the battery case.  In the case of polypropylene batteries 
the electrolyte level must not be below the minimum mark indicated on the case.  
Only add distilled water to the battery! 
1. When working with the battery, first read the attached manual! 
2. During work with the battery protect your eyes with goggles or a safety shield! 
3. The electrolyte is a caustic substance; therefore, handle it with proper care. If 
your skin or clothes get stained by electrolyte, wash the skin or clothes with wa-
ter and neutralize them with soap.  Keep the battery out of reach of children! 
4. During charging hydrogen is released from the electrolyte on the electrodes. Hy-
drogen mixed with the air forms an explosive mixture.  Therefore, it is prohibited 
to handle open fire near the battery during charging. 
5. An explosion may also be caused by a spark created on the disconnection or re-
lease of a terminal when the charging circuit is on.  
6. A discarded battery is dangerous waste for the environment - when buying a new 
battery hand the old one over to the dealer, who will dispose of it free of charge.  