169
MAINTENANCE INSTRUCTIONS
E704 E705
REPLACING THE FULL-FLOW
ENGINE OIL CLEANER
The cleaner is replaced at every engine
oil replacement. Before installing the new
cleaner clean the sealing surface of the
housing (1) and the cleaner (2). Coat the
rubber sealing with oil that you will fill the
engine with and tighten the cleaner by
hand. When the sealing gets in contact
with the block sealing, tighten the
cleaner again by 3/4 to 1 1/4 turns.
Check the cleaner for possible leaks af-
ter starting the engine.
FILLING THE ENGINE WITH OIL
Pour the prescribed quantity of engine oil
into the filling opening (2), start the en-
gine and let it run for 2 - 3 minutes at 750
- 800 rpm.
After stopping of the engine and level
stabilization use the dipstick (1) to check
the oil level and check the cleaner, drain
plug (3) and other joints for leaks.