1-4 
 
z  By default, the PoE function on a port is enabled by the default configuration file config.def when 
the device is delivered. 
z  If you delete the default configuration file without specifying another one, the PoE function on a port 
will be disabled after you restart the device. 
 
Setting the Maximum Output Power on a Port 
The maximum power that can be supplied by each Ethernet electrical port of a PoE-enabled Switch 
4210 to its PD is 15,400 mW. In practice, you can set the maximum power on a port depending on the 
actual power of the PD, in the range of 100 to 15,400 mW and in the granularity of 1 mW. 
Table 1-4 Set the maximum output power on a port 
Operation  Command  Description 
Enter system view 
system-view 
— 
Enter Ethernet port view 
interface interface-type 
interface-number 
— 
Set the maximum output power 
on the port 
poe max-power max-power 
Required 
15,400 mW by default. 
 
Setting PoE Management Mode and PoE Priority of a Port 
When a switch is close to its full load in supplying power, you can adjust the power supply of the switch 
through the cooperation of the PoE management mode and the port PoE priority settings. Switch 4210 
support two PoE management modes, auto and manual. The auto mode is adopted by default.  
z  auto: When the switch is close to its full load in supplying power, it will first supply power to the PDs 
that are connected to the ports with critical priority, and then supply power to the PDs that are 
connected to the ports with high priority. For example: Port A has the priority of critical. When the 
switch PoE is close to its full load and a new PD is now added to port A, the switch will power down 
the PD connected to the port with the lowest priority and turn to supply power to this new PD. If 
more than one port has the same lowest priority, the switch will power down the PD connected to 
the port with larger port number. 
z  manual: When the switch is close to its full load in supplying power, it will not make change to its 
original power supply status based on its priority when a new PD is added. For example: Port A has 
the priority critical. When the switch PoE is close to its full load and a new PD is now added to port 
A, the switch just gives a prompt that a new PD is added and will not supply power to this new PD. 
After the PoE feature is enabled on the port, perform the following configuration to set the PoE 
management mode and PoE priority of a port. 
Table 1-5 Set the PoE management mode and PoE priority of a port 
Operation  Command  Description 
Enter system view 
system-view 
—