1-7
Table 1-5 Manually remove history password records
Operation Command Description
Remove history
password records
of one or all users
reset
password-control
history-record
[ user-name
user-name ]
Executing this command without the user-name
user-name option removes the history password
records of all users.
Executing this command with the user-name
user-name option removes the history password
records of the specified user.
Remove history
records of one or all
super passwords
reset
password-control
history-record super
[ level level-value ]
Executing this command without the level
level-value option removes the history records of all
super passwords.
Executing this command with the level level-value
option removes the history records of the super
password for the users at the specified level.
Configuring a User Login Password in Interactive Mode
A password can be a combination of characters from the following four types: letters A to Z, a to z,
numbers 0 to 9, and 32 special characters (including the space and ~ ` ! @ # $ % ^ & * ( ) _ + - = { } | [ ]
\ : ” ; ’ < > , . / ).
The password must conform to the related configuration of password control when you set the local
user password in interactive mode.
Table 1-6 Configure a user login password in interactive mode
Operation Command Description
Enter system view
system-view
—
Enter the specified user view
l
ocal-user user-name
—
Configure a user login password
in interactive mode
password
Optional
Input a password according to the
system prompt and ensure the two
input passwords are consistent.
Configuring Login Attempt Times Limitation and Failure Processing Mode
Table 1-7 Configure the login attempts limitation and the failure processing mode
Operation Command Description
Enter system view
system-view
—
Enable the login attempts
limitation, configure the maximum
number of attempts and configure
the processing mode used when
the maximum number of attempts
is exceeded.
password-control
login-attempt
login-times [ exceed
{ lock | unlock |
lock-time time } ]
Optional
By default, the maximum number of
attempts is three, and the switch
operates in the lock-time processing
mode when the maximum number of
attempts is exceeded.
When the maximum number of attempts is exceeded, the system operates in one of the following
processing mode: