1-8
z If the system information is output before you input any information following the current command
line prompt, the system does not echo any command line prompt after the system information
output.
z In the interaction mode, you are prompted for some information input. If the input is interrupted by
system output, no system prompt (except the Y/N string) will be echoed after the output, but your
input will be displayed in a new line.
Configuring to Display the Time Stamp with the UTC Time Zone
To add UTC time zone to the time stamp in the information center output information, you must:
z Set the local time zone
z Set the time stamp format in the output direction of the information center to date
z Configure to add the UTC time zone to the output information
Table 1-6 Configure to display time stamp with the UTC time zone
Operation Command Description
Set the time zone for the system
clock timezone zone-name
{ add | minus } time
Required
By default, UTC time
zone is set for the
system.
Enter system view
system-view
Log host
direction
info-center timestamp
loghost date
Set the time stamp
format in the output
direction of the
information center
to date
Non log host
direction
info-center timestamp { log |
trap | debugging } date
Required
Use either command
Set to display the UTC time zone in
the output information of the
information center
info-center timestamp utc
Required
By default, no UTC time
zone is displayed in the
output information
Setting to Output System Information to the Console
Setting to output system information to the console
Table 1-7 Set to output system information to the console
Operation Command Description
Enter system view
system-view
Enable the information
center
info-center enable
Optional
Enabled by default.