EasyManua.ls Logo

3Com 4210 PWR - Page 563

3Com 4210 PWR
567 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Password Control Configuration 561
Configuring Login
Attempt Times
Limitation and Failure
Processing Mode
When the maximum number of attempts is exceeded, the system operates in one
of the following processing mode:
lock-time: In this mode, the system inhibits the user from re-logging in within
a certain time period. After the period, the user is allowed to log into the
switch again. By default, this time is 120 minutes.
lock: In this mode, the system inhibits the user from re-logging in forever. The
user is allowed to log into the switch again only after the administrator
removes the user from the user blacklist.
unlock: In this mode, the system allows the user to log in again.
c
CAUTION:
Login attempt times limitation and failure processing are not supported for FTP
and Super passwords.
The number of retries allowed to enter an SSH password is determined by the
configuration of the SSH server instead of that configured by using the
password-control login-attempt command. You can use the
password-control login-attempt command to configure the actions to be
taken when the number of retries to enter the SSH password exceeds the
configured value. Refer to
“SSH Configuration” on page 387 for information
about SSH server.
If a user in the blacklist changes his/her IP address, the blacklist will not affect
the user anymore when the user logs into the switch.
The system administrator can perform the following operations to manually
remove one or all user entries in the blacklist.
Configure a user login
password in interactive
mode
password Optional
Input a password according
to the system prompt and
ensure the two input
passwords are consistent.
Table 413 Configure a user login password in interactive mode
Operation Command Description
Tab le 414 Configure the login attempts limitation and the failure processing mode
Operation Command Description
Enter system view system-view -
Enable the login attempts
limitation, configure the
maximum number of
attempts and configure
the processing mode used
when the maximum
number of attempts is
exceeded.
password-control
login-attempt login-times [
exceed { lock | unlock |
lock-time time } ]
Optional
By default, the maximum
number of attempts is three,
and the switch operates in
the lock-time processing
mode when the maximum
number of attempts is
exceeded.

Table of Contents