1-21
To do… Use the command… Remarks
Configure the automatic test
interval
frequency interval
Optional
By default, the automatic test
interval is zero seconds,
indicating no automatic test will
be made.
Configure the probe timeout
time
timeout time
Optional
By default, a probe times out in
three seconds.
Configure the type of service
tos value
Optional
By default, the service type is
zero.
Configure the domain name to
be resolved
dns resolve-targetdomai
domainname
Required
By default, the domain name to
be resolved by DNS is not
specified.
Configure the IP address of the
DNS server
dns-server ip-address
Required
By default, no DNS server
address is configured.
Start the test
test-enable
Required
Display test results
display remote-ping results
[ admin-name operation-tag ]
Required
The display command can be
executed in any view.
10) Clear all agents on the remote-ping client
Follow these steps to clear all agents on the remote-ping client:
To do… Use the command… Remarks
Enter system view
system-view
Clear all agents on the
remote-ping client
remote-ping-agent clear
Required
z This command clears all the configured agents, including the test configuration, test result, and
history information.
z The result cannot be restored after the execution of the command.
z The command does not disable remote-ping-agent.
Configuring remote-ping client to send Trap messages
Trap messages are generated regardless of whether the remote-ping test succeeds or fails. You can
specify whether to output Trap messages by enabling/disabling Trap sending.
Follow these steps to configure the remote-ping client to send Trap messages: