EasyManua.ls Logo

3Com 5500-EI PWR - Page 995

3Com 5500-EI PWR
1072 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-16
To do… Use the command… Remarks
Configure the probe timeout
time
timeout time
Optional
By default, a probe times out in
three seconds.
Configure the type of service
tos value
Optional
By default, the service type is
zero.
Start the test
test-enable
Required
Display test results
display remote-ping results
[ admin-name operation-tag ]
Required
You can execute the command
in any view.
7) Configuring TCP test on remote-ping client
Follow these steps to configure TCP test on remote-ping client:
To do… Use the command… Remarks
Enter system view
system-view
Enable the remote-ping
client function
remote-ping-agent enable
Required
By default, the remote-ping client
function is disabled.
Create a remote-ping
test group and enter its
view
remote-ping
administrator-name
operation- tag
Required
By default, no test group is configured.
Configure the destination
address
destination-ip ip-address
Required
This IP address and the one configured
on the remote-ping server for listening
services must be the same.
By default, no destination address is
configured.
Configure the destination
port
destination-port
port-number
Required in a Tcpprivate test
A Tcppublic test is a TCP connection
test on port 7. Use the
remote-ping-server tcpconnect
ip-address 7 command on the server to
configure the listening service port;
otherwise the test will fail. No port
number needs to be configured on the
client; any destination port number
configured on the client will not take
effect.
By default, no destination port number is
configured.
Configure the source IP
address
source-ip ip-address
Optional
By default, the source IP address is not
specified.
Configure the source
port
source-port port-number
Optional
By default, no source port is specified.
Configure the test type
test-type { tcpprivate |
tcppublic }
Required
By default, the test type is ICMP.

Table of Contents

Other manuals for 3Com 5500-EI PWR

Related product manuals