Operation Manual / 4 Product description / A130-M.. - A145-M..
5
Operation and service
Page 42 /
121
© Copyright 2017 ABB. All rights reserved.
HZTL4031_EN
Revision E
January 2017
Influencing parameters
The specified values are guideline values and are not guaranteed. The actual values can de-
viate considerably from the guideline values, for example, due to the following influences:
Fuel quality and fuel treatment
Load profile (thermal cycling, also number of starts/stops, emergency shutdowns, operat-
ing point)
Gas inlet temperature
Frequency and execution of cleaning process during operation
Turbocharger specification.
System-specific operating conditions (combustion quality, exhaust gas composition)
For bearing parts
Lubricating oil quality (oil filtering, oil condition, oil monitoring)
Load profile (speed, pressure conditions, temperature)
Number of starts/stops
Unbalance of the rotor (degree of contamination).