Operation Manual / 4 Product description / A130-M.. - A145-M..
6
Periodic maintenanc
e work Page 59 /
121
© Copyright 2017 ABB. All rights reserved.
HZTL4031_EN
Revision E
January 2017
Spray cleaned surfaces with penetrating oil. Do not spray exterior surfaces of the turbo-
charger.
Dispose of contaminated water and cleaning agents in accordance with the information in
the material safety data sheet.
6.4.5 Cartridge group, general
CAUTION
Corrosion
If the cartridge group is not put back into operation immediately after clean-
ing, parts may corrode.
Immediately after cleaning, install the cartridge group and put it back into
operation.
There can be severe contamination of the compressor wheels due to badly filtered suction air
and of the turbines because of heavy fuel oil operation or carbonized oil. Cleaning during op-
eration may not suffice to remove such contamination; instead, it may need to be cleaned me-
chanically during standard service intervals (see chapter service work).
Remove turbocharger from engine (see chapter Removing and Installing [➙ 11]).
Remove cartridge group (see chapter Dismantling and fitting [➙ 73]).
First clean the compressor end and then the turbine end according to the following descrip-
tion.