Communication with Modbus
A43/A44 110 2CMC48001M0201
User Manual Revision: C
Quantity
Details
Start reg (Hex)
Size
Res.
Unit
Data type
Reactive import
L1
5484
4
0,01
kvarh
Unsigned
Reactive import
L2
5488
4
0,01
kvarh
Unsigned
Reactive import
L3
548C
4
0,01
kvarh
Unsigned
Reactive export
L1
5490
4
0,01
kvarh
Unsigned
Reactive export
L2
5494
4
0,01
kvarh
Unsigned
Reactive export
L3
5498
4
0,01
kvarh
Unsigned
Reactive net
L1
549C
4
0,01
kvarh
Signed
Reactive net
L2
54A0
4
0,01
kvarh
Signed
Reactive net
L3
54A4
4
0,01
kvarh
Signed
Apparent import
L1
54A8
4
0,01
kVAh
Unsigned
Apparent import
L2
54AC
4
0,01
kVAh
Unsigned
Apparent import
L3
54B0
4
0,01
kVAh
Unsigned
Apparent export
L1
54B4
4
0,01
kVAh
Unsigned
Apparent export
L2
54B8
4
0,01
kVAh
Unsigned
Apparent export
L3
54BC
4
0,01
kVAh
Unsigned
Apparent net
L1
54C0
4
0,01
kVAh
Signed
Apparent net
L2
54C4
4
0,01
kVAh
Signed
Apparent net
L3
54C8
4
0,01
kVAh
Signed
Resettable energy accumulators
All registers in the following table are read only:
Quantity
Start reg
Size
Res.
Unit
Data type
(Hex)
Resettable active
552C
4
0,01
kWh
Unsigned
import
Resettable active
5530
4
0,01
kWh
Unsigned
export
Resettable
5534
4
0,01
kWh
Unsigned
reactive import
Resettable
5538
4
0,01
kWh
Unsigned
reactive export

Table of Contents