44 Start-up
Parameter table revision
29 FBA drive type
code
Read-only. Displays the drive type
code of the fieldbus adapter
module mapping file stored in the
memory of the drive.
N/A
Drive type code of the fieldbus
adapter module mapping file
30 FBA mapping file
ver
Read-only. Displays the fieldbus
adapter module mapping file
revision stored in the memory of
the drive in decimal format.
N/A
Mapping file revision
31 D2FBA comm
status
Read-only. Displays the status of
the fieldbus adapter module
communication.
Note: The value names may vary
by drive.
0 = Idle
OR
4 = Off-
line
0 = Idle/Not
configured
Adapter is not configured.
1 = Exec.init/
Initializing
Adapter is initializing.
2 = Time out A timeout has occurred in the
communication between the
adapter and the drive.
3 = Conf.err/
Configuration error
Adapter configuration error: The
major or minor revision code of the
common program revision in the
fieldbus adapter module is not the
revision required by the module or
mapping file upload has failed
more than three times.
4 = Off-line Adapter is off-line.
5 = On-line Adapter is on-line.
6 = Reset Adapter is performing a hardware
reset.
No. Name/Value Description Default