EasyManuals Logo

ABB HT611036 User Manual

ABB HT611036
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Operation Manual / A150-M56/66/57/67 - A155-M..
4 Commissioning / 4.2 Inspection procedures
© Copyright 2021 ABB. All rights reserved. HZTL4032_EN Rev.Q January 2021
4.2.3 Checks after commissioning (engine in idle mode)
Lubricating system
u Keep to the lubricating oil pressure at the inlet.
u Keep to the lubricating oil temperature at the inlet.
u Refer to chapter Monitoring operation →44 for admissible values.
Gas, air and oil pipes
u After starting the engine, check all gas, air and oil pipes for leaks.
4.2.4 Checks when starting up the engine
If present:
u Measure speed, oil pressure and charging pressure at various engine performances.
u Measure the exhaust gas temperature before and after the turbine.
u Measure the air temperature before and after the compressor.
u Compare the measured values with the values of the acceptance report. Different operat-
ing conditions indicate a malfunction (see chapter Eliminating malfunctions →78).
Lubricants and pastes used during assembly can liquefy or vaporise and escape as oily fluids
during the initial hours of operation. Continual escape of an oily fluid indicates an oil leak. If
there is a leak, contact an ABB Turbocharging Service Station.
Page 42 / 194

Table of Contents

Other manuals for ABB HT611036

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HT611036 and is the answer not in the manual?

ABB HT611036 Specifications

General IconGeneral
BrandABB
ModelHT611036
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals