6.4 Stopping the engine
CAUTION
Residual heat in the turbocharger
If the residual heat in the turbocharger is not adequately dissipated, it may
damage the engine.
u Adequate cooling of the turbocharger must be ensured after stopping
the engine.
u Run the engine for 2…10 minutes at idling speed before stopping it.
u Observe the oil pressure specified for engine idling (see Table7: Lubricating oil pressure
at oil inlet before turbocharger 45).
¡ For oil-cooled bearing casings, post-lubricate for 20minutes if the turbine inlet temper-
ature (t
TE
) exceeds the following values when the engine is stopped:
550°C with insulated casing
600°C with non-insulated casing
At temperatures below the specified values, post-lubrication must be ensured until the
rotors come to a standstill. Turbo Systems recommends post-lubrication for 10minutes.
u Observe the oil pressure specified for post-lubrication (see Table7: Lubricating oil pres-
sure at oil inlet before turbocharger 45).