NoteAction
WARNING
Before continuing any service work, please
observe the safety information in section
WARNING - The brake release buttons may
be jammed after service work on page 46!
6
Shown in the figure Location of brake
release unit on page 174.
Refit the push button guard to the SMB cover.7
Detailed in the Calibration chapter -
section Updating revolution counters
on page 335.
If the battery has been disconnected the revolu-
tion counter must be updated.
8
DANGER
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in the section DANGER - First
test run may cause injury or damage! on
page 45.
9
3HAC039838-001 Revision: C 177
© Copyright 2013 ABB. All rights reserved.
4 Repair
4.3.4 Replacing the brake release unit
Continued