Note/IllustrationAction
xx2200001972
Push the digital base into the bracket
until you hear a clear clicking sound.
3
Connect the adapter cable to the digital
base.
• K5.1.X5/K3.1.X5 - A2.X4/K4.X7
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector K5.1.X5/K3.1.X5
to/from K4.X7.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector
K5.1.X5/K3.1.X5 to/from A2.X4.
• K5.1.X4 - A2.X3
• The harness connected to I/O unit
by customer
4
Concluding procedure
Note/IllustrationAction
Closing the door on page 183.Close the door.1
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 171.
2
Product manual - OmniCore V400XT 121
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.2 Installing the safety digital base device
Continued