3.7.11 Installing the motor connection box
Location
The motor connection box location is decided by the customer.
Required tools and equipment
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 424.
-Standard toolkit
-ESD protective wrist band
Note
It is the responsibility of the integrator to install a quenching circuit when
connecting third party motors.
Required documents
NoteArticle numberDocument
3HAC082020-008Circuit diagram - OmniCore
V400XT
Installing the motor connection box
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Note
Due to the stiffness of the floor cables, the
minimum required space beside the motor
connection box is 330 on the left side and
180 on the right side.
Fit the motor connection box in its loca-
tion. Secure with screws.
2
If third party motors are to be connected,
install a quenching circuit.
3
Continues on next page
154 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.11 Installing the motor connection box