Loading...
NoteArticle numberEquipment
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC082020-008Circuit diagram - OmniCore
V400XT
Installing the DeviceNet board
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Opening the door on page 182.Open the door.2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2300001842
Installing the DeviceNet board
Note/IllustrationAction
Loosen the screws that hold the cover
plate.
1
Remove the cover plate from the main
computer assembly.
2
Insert the DeviceNet board into the slot
in the main computer assembly.
3
Continues on next page
152 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.10 Installing the DeviceNet board
Continued